TROUBLESHOOTING & REPAIR |
| |||
Observe Safety Guidelines |
|
| TROUBLESHOOTING GUIDE | |
detailed in the beginning of this manual. |
|
| ||
|
|
| ||
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
| |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
| |
|
|
|
|
|
|
| ENGINE PROBLEMS |
|
|
The engine shuts down shortly after | 1. | Check for adequate fuel supply. | 1. Check the Run/Stop switch and |
|
starting. | 2. | If any indicator light is lit when | associated leads for loose or |
|
| faulty connections. |
| ||
|
| the engine shuts down, that par- |
| |
|
|
|
| |
|
| ticular system has faulted. | 2. Perform the Fuel Shutdown |
|
|
| Check system. | Solenoid Test. |
|
| 3. Check the battery cables for | 3. The engine protection board |
| |
|
| loose or faulty connections. | may be faulty. With the Run/ |
|
|
|
| Stop switch in the “Run” posi- | |
|
|
| tion, the protection board should | |
|
|
| normally supply 10VDC to the | |
|
|
| shutdown solenoid via leads | |
|
|
| #224 and #262. See the Wiring | |
|
|
| Diagram. | |
|
|
|
| |
The engine will not idle down to low | 1. | Make sure the idler switch is in | 1. Perform the Idler Solenoid | |
speed. The machine has normal |
| the “Auto” position. | Test. | |
weld output and auxiliary power. | 2. Make sure there is NOT an | 2. The engine protection board | ||
| ||||
|
| external load on the weld termi- | may be faulty. | |
|
| nals nor the auxiliary power |
|
|
|
| receptacles. |
|
|
| 3. Check for mechanical restric- |
|
| |
|
| tions in the solenoid linkage. |
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call