TROUBLESHOOTING & REPAIR

OUTPUT RECTIFIER BRIDGE TEST (continued)

FIGURE F.23 – OUTPUT PANEL REMOVAL

OUTPUT LEADS (BEHIND PANEL)

GREEN

GROUND

LEAD

 

 

SCREWS

 

7. Using the

3/8" wrench,

remove the five

8.

Using the 7/16" wrench, remove the stator

screws holding the lower front panel to the

 

leads and diode pigtail leads from the three

case front

assembly.

See Figure F.23.

 

studs. Label the leads for reassembly. Note

Carefully move the lower front panel to the

 

leads and pigtail placement for reassembly.

right side.

Note that he green ground lead

 

See Figure F.24.

will still be attached.

 

 

 