Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
STATOR/ROTOR REMOVAL AND REPLACEMENT (continued)
FIGURE F.46 – BRUSH LEAD REMOVAL
#200A
#200B
#201
Return to Section TOC
Return to Master TOC
12.Label and remove brush leads
13.Pull the harness containing plug J30, the brush leads, and the field bridge rectifier through the bushing in the firewall. See
Figure F.45.
14.Using the 3/8" wrench, remove the brush holder assembly.
15.Using the 1/2" wrench, disconnect leads #68A and #69A at their bolted connections beneath the power module assembly. Label the leads for reassembly. Cut any neces- sary cable ties. See Figure F.47.
Return to Section TOC
Return to Master TOC