TROUBLESHOOTING & REPAIR
RETEST AFTER REPAIR
Retest a machine:
•If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR
•If you repair or replace any electrical components.
ENGINE OUTPUT
Mode | No Load RPM | Load RPM |
Low Idle | 1350 - 1400 | NA |
High Idle | 1880 - 1919 | 1780 - 1820 |
|
|
|
WELDER DC (STICK) OUTPUT
Mode Selector | Fine Control | Open Circuit | Load Volts | Load Amps |
Switch |
| Volts |
|
|
Maximum | ||||
|
|
|
|
|
PIPE MODES SHORT CIRCUIT CURRENT
(FINE CONTROL AT MAXIMUM)
Selector Position | Short Circuit Current (Amps) |
60 | |
90 | |
150 | |
230 | |
300 | |
|
|
WELDER CV (WIRE) OUTPUT
Mode Selector | Fine Control | Open Circuit | Load Volts | Load Amps |
Switch |
| Voltage |
|
|
CV Mig/Mag | Maximum | |||
CV Mig/Mag | Maximum | 20 | ||
CV Mig/Mag | Minimum | 20 | ||
|
|
|
|
|
AUXILIARY POWER OUTPUT
| 230 Volt Receptacle |
|
| 115 Volt Receptacles |
|
| ||||
Open Circuit |
| Load Volts |
| Load Amps | Open Circuit |
| Load Volts |
| Load Amps |
|
Voltage |
|
|
|
| Voltage |
|
|
|
|
|
230 - 264 |
|
| 44 | 115 - 132 |
| 108 - 132 |
| 15 |
| |
|
|
|
|
|
|
|
|
|
|
|