Lincoln Electric SVM145-B service manual Troubleshooting & Repair

Models: SVM145-B

1 175
Download 175 pages 51.13 Kb
Page 97
Image 97

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-41

F-41

TROUBLESHOOTING & REPAIR

STATOR VOLTAGE TEST (continued)

FIGURE F.17 – OUTPUT RECTIFIER DIODE BRIDGE

WELD WINDING

LEAD CONNECTIONS

Return to Section TOC

Return to Master TOC

4.Locate the weld winding leads connected to the three-phase output rectifier diode bridge. See Figure F.17.

5.Check for approximately 68VAC from W1 to W2. Also check from W2 to W3 and from W1 to W3.

6.If any of these voltages are low or missing perform the Rotor Flashing and Voltage Test and also the Rotor Resistance Test.

7.Also check leads #6H and #5P for loose or faulty connections to the field bridge. See the Wiring Diagram.

8.If the tests in Steps 6 and 7 are OK and the stator voltages are low or missing, the sta- tor may be faulty.

9.Replace the lower front panel and output leads.

10.Replace the upper control panel and secure.