TROUBLESHOOTING & REPAIR

POWER MODULE TEST (continued)

FIGURE F.27 – DIODE MODULE TEST

DIODE MODULES

AND HEAT SINKS

Return to Section TOC

Return to Master TOC

CHECK DIODE MODULE

8.Using the analog ohmmeter, connect the negative meter probe to the terminal on the diode module. See Figure F.27. Connect the positive meter probe to the heat sink. The resistance should be very high (over 20,000 ohms).

9.Using the analog ohmmeter, connect the positive meter probe to the terminal on the diode module. See Figure F.27. Connect the negative meter probe to the heat sink. The resistance should be low (approximately 1000 ohms).

10.Reconnect all leads and sheet metal previ- ously removed.

11.Torque the capacitor nuts to 50-60 inch- pounds.

Return to Section TOC

Return to Master TOC

COMMANDER 300

Page 114
Image 114
Lincoln Electric SVM145-B service manual Check Diode Module, Figure F.27 Diode Module Test