F-7

 

 

 

 

 

 

F-7

TROUBLESHOOTING & REPAIR

 

 

 

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

 

 

The output control on the

 

1. Make sure the Remote/Local

1.

Check the Remote/Local switch

Commander 300 does not work

 

switch is in the “Local” position.

 

and associated wiring. See the

properly.

 

2. The output control (R1) may be

 

Wiring Diagram. (leads

#75,

 

 

 

 

#76 and #77)

 

 

 

 

 

 

defective.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Perform

the

Power

Supply

 

 

 

 

Test.

 

 

 

 

 

 

 

 

3.

Perform

the

Control

Input

 

 

 

 

Test.

 

 

 

 

 

 

 

 

4.

Perform

the

Feedback

Input

 

 

 

 

Test.

 

 

 

 

 

 

 

 

5.

Perform the PWM Output Test.

 

 

 

6.

Perform

the

Power

Module

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

 

 

The remote output control does not

 

1. Make sure the Remote/Local

1.

Check the Remote/Local switch

function properly.

 

switch is in the “Remote” posi-

 

and associated leads. See the

 

 

tion.

 

Wiring Diagram.

 

 

 

 

 

2. The remote control unit may be

2.

Check

the

amphenols

and

 

 

faulty. Repair or replace.

 

associated leads.

See the

 

 

 

 

Wiring Diagram.

 

 

 

 

 

 

3.

Perform the RF Bypass Board

 

 

 

 

Resistance Test.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION