
MAINTENANCE
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
COOLING BLOWER BELT: The following procedure should be followed to replace the cooling blower belt:
1.Allow the machine to cool.
2.Remove the engine case side.
3.Loosen the air filter hose clamp and detach hose.
4.Disconnect the negative battery cable.
5.Remove the engine case back panel for access to the engine.
6.Remove the pulley belt guard (5 screws).
7.Remove the rubber strap on the lower half of the engine fan cowling. Loosen the tensioning pulley (2 bolts).
8.Remove the old
9.Reinstall the rubber strap on the fan cowling, the pulley belt guard, the engine case back, the air fil- ter hose, and the engine case side.
10.Reconnect the negative battery terminal.
SPARK ARRESTER SCREEN: If the muffler has the optional spark arrester, remove it every 50 hours or once a year, whichever comes first, and inspect it. Clean the arrester. Replace it if you find any damage.
Return to Section TOC
Return to Master TOC