Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| TROUBLESHOOTING & REPAIR |
|
|
|
|
|
|
| |||||||||
| Observe Safety Guidelines |
|
|
|
|
|
|
| TROUBLESHOOTING GUIDE | ||||||||
| detailed in the beginning of this manual. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||||||||
| PROBLEMS | POSSIBLE AREAS OF |
| RECOMMENDED |
|
|
|
|
| ||||||||
| (SYMPTOMS) | MISADJUSTMENT(S) |
|
| COURSE OF ACTION |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
|
|
|
|
| ||||
| Major physical or electrical damage | 1. | Contact your | local | Lincoln |
| 1. Contact the Lincoln Electric |
| |||||||||
| is evident. |
| Authorized Field Service Facility. |
|
| Service Department at |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||||||||||
| No welding output in neither Stick | 1. Place | the | Welding Terminals |
| 1. Check for loose or faulty connec- |
| ||||||||||
| or CV modes. The engine operates |
| Switch in the “ALWAYS ON” |
|
| tions on the heavy current carry- |
| ||||||||||
| normally. The auxiliary output is |
| position. | If the problem is |
|
| ing leads between the output, |
| |||||||||
| normal. |
| solved, the fault may be in the |
|
| the power modules, the choke |
| ||||||||||
|
|
| external control cable (if used), |
|
| and the output terminals. |
|
|
| ||||||||
|
|
| leads #2 and #4. See the Wiring |
| 2. | Check | the | Welding | Terminals |
| |||||||
|
|
| Diagram. |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
| Switch | and | associated | leads. |
| |||||
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| 2. With | the engine at high idle |
|
| See the Wiring Diagram. |
|
|
| ||||||||
|
|
| (1900 RPM), the machine in the |
| 3. | If the | correct OCV | is present |
| ||||||||
|
|
| Stick | mode | and | the OUTPUT |
|
| |||||||||
|
|
|
|
| when | the | Welding | Terminals |
| ||||||||
|
|
| CONTROL at maximum, check |
|
|
| |||||||||||
|
|
|
|
| Switch is in the “ALWAYS ON” |
| |||||||||||
|
|
| for the presence of approximate- |
|
|
| |||||||||||
|
|
|
|
| position, perform the RF Bypass |
| |||||||||||
|
|
| ly 87VDC (open circuit voltage at |
|
|
| |||||||||||
|
|
|
|
| Board | Resistance | Test. | Also |
| ||||||||
|
|
| the output terminals. |
|
|
|
| ||||||||||
|
|
|
|
|
| check | associated | wiring. | See |
| |||||||
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| 3. | If the correct OCV is present at |
|
| the Wiring Diagram. |
|
|
|
| |||||||
|
|
| the welding output terminals, |
| 4. Check the Remote/Local switch |
| |||||||||||
|
|
| check | the | welding | cables, |
|
| |||||||||
|
|
|
|
| and associated wiring. See the |
| |||||||||||
|
|
| clamps and electrode holder for |
|
|
| |||||||||||
|
|
|
|
| Wiring Diagram. (leads #75, #76 |
| |||||||||||
|
|
| loose or faulty connections. |
|
|
| |||||||||||
|
|
|
|
| and #77) |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| 4. | Make | sure | that | the |
| 5. | Perform the Stator Voltage |
| |||||||
|
|
| LOCAL/REMOTE switch is in the |
|
| ||||||||||||
|
|
|
|
| Test. |
|
|
|
|
|
|
| |||||
|
|
| correct position. |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| 6. Perform the Output Rectifier |
| ||||||||||
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| Bridge Test. |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| 7. Perform the Power Module |
| |||||||
|
|
|
|
|
|
|
|
|
| Test. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8. Perform the Control Trans- |
| |||||||
|
|
|
|
|
|
|
|
|
| former Test. |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| 9. Perform the Power Supply |
| |||||||
|
|
|
|
|
|
|
|
|
| Test. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10. Perform the Control Input Test. |
| |||||||
|
|
|
|
|
|
|
|
| 11. Perform the Feedback Input |
| |||||||
|
|
|
|
|
|
|
|
|
| Test. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 12. Perform the PWM Output Test. |
| |||||||
|
|
|
|
|
|
|
|
| 13. Perform the Current Balance |
| |||||||
|
|
|
|
|
|
|
|
|
| Test (codes 10469 & 10470). |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call