F-78

F-78

TROUBLESHOOTING & REPAIR

DISPLAY BOARD CALIBRATION TEST (continued)

Return to Section

Return to Section TOC

TOC

Return to Master

Return to Master TOC

TOC

TEST PROCEDURE

1.Start the engine.

2.Turn the range selector switch to the CC posi- tion, and control dial to the min. position.

3.With no load applied, slowly turn the control dial clockwise from min to max in each range selector switch position. The display should read the same as the Table F.5 shown below.

4.If the display reading is off in any mode, the display board must be re-calibrated.

RE-CALIBRATION PROCEDURE

5.Turn the engine off.

6.Set the control panel switches as follows:

Welding Terminals switch to “Remotely Controlled”.

Local/Remote switch to “Remote”.

Range Selector switch to “60A”.

Control Dial to “Min”.

Idler Switch to “High”.

Arc Control Wire/Stick dial to “Min”.

7.Start the engine.

8.Within 5 seconds after the top display reads

“Crd”, switch the range selector switch to the CV position and back to the 60A position a minimum of 5 times. Must end up in the 60A position.

9.The top display should read “001” for about 5 seconds, then read “CAL” for about 5 sec- onds. The top display will then read “30”. The bottom display will read “---”. This com- pletes the calibration process.

10.Repeat steps 2 & 3.

11.If the display is still off, turn the engine off.

12.Perform the Case Cover Removal and Replacement Procedure and tilt the control panel out.

13.Check all leads at J8 & J9 at the display board for continuity and poor connection. See the Wiring Diagram. Check for broken molex pins.

14.If all the leads are ok, perform steps 5 & 6 of the Control Input Test. Measure the volt- ages in step 6 at J8 pin 3 (pos. lead) to J9 pin 5 (neg. lead) instead of measuring at the J2 connector on the control board.

15.Turn the engine off.

16.If any of the voltages were wrong, replace the control board. If the voltages were ok, replace the display board.

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

 

Table F.5.

 

RANGE SELECTOR SW. POSITION

FROM MIN.

TO MAX.

CC

30 amps

375 amps

300A

140 amps

300 amps

230A

100 amps

230 amps

150A

70 amps

150 amps

90A

50 amps

90 amps

60A

30 amps

60 amps

CV

10.5 volts

49-50 volts

COMMANDER 300

Page 134
Image 134