Furuno manual Wiring, Follow the illustration below to wire the IB-782

Page 19

4.2 Wiring

Follow the illustration below to wire the IB-782.

MULTI-COMMUNICATION UNIT IB-782

TEL8 - TEL1 LINE

LN8-LN1 LN0

P OW E R 100V-220VAC 50-60Hz

1 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-220 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Cable (supplied)

 

 

 

 

Ground Terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To Communication Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IB-282

CAUTION

Ground the equipment to prevent electrical shock and mutual interference.

TEL3

5

6

 

 

Junction Box

 

 

IB-313

Local Supply (Use TTYCS-1

 

 

(Japan Industrial Standard) or equivalent.)

 

 

 

Armor

 

 

Shield

 

Conductor

Vinyl sheath

Rosette

 

 

MJ-2S

S =1.25 mm2

Painting

 

=1.35 mm

 

 

 

TTYCS-1 sectional view

To Telephone (or FAX)

To Telephone (or FAX)

Modular Jack Cable (supplied)

Facsimile

Facsimile

Telephone

Telephone

 

Wiring

11

Image 19
Contents MULTI-COMMUNICATION Unit B . N o . O M E 5 6 0 9 Safety Instructions Safety Instructions for the Installer Table of Contents Foreword FeaturesWord to the Owner of the IB-782 Antenna Unit System ConfigurationName Type Qty Remarks Equipment ListEquipment Overview OperationReceiving CallingCalling IB-782’s telephones IntercomCalling communication unit’s telephones Automatic Call Forwarding Forwarding a CallReceive-Only Telephone PBX Mode Settings SettingsOID/DID Setting Changing Number for Connection to Inmarsat Services DIP Switch SettingCleaning MaintenanceMounting considerations InstallationMounting procedure MountingFollow the illustration below to wire the IB-782 WiringIB-782 Specifications of the MULTI-COMMUNICATION Unit