Icom IC-F3GS, IC-F3GT service manual Software Adjustment, Txf

Page 16

5-3 SOFTWARE ADJUSTMENT

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

MEASUREMENT

 

 

VALUE

 

 

 

 

 

 

 

UNIT

 

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFERENCE

 

1

• Operating frequency:

Top

Loosely

couple a

frequnecy

136.00000 MHz

FREQUENCY

 

 

136.000 MHz (L-band)

panel

counter to the antenna connec-

 

(L-band)

[TXF]

 

 

146.000 MHz (H-band)

 

tor.

 

 

146.00000 MHz

 

 

 

• High/Low switch

: Low

 

 

 

 

 

(H-band)

 

 

 

• Connect the RF power meter or 50 Ω

 

 

 

 

 

 

 

 

 

 

dummy load to the antenna connector.

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Transmitting

 

 

 

 

 

136.001360 MHz

 

 

 

 

 

 

 

 

 

 

(L-band)

 

 

 

 

 

 

 

 

 

146.001460 MHz

 

 

 

 

 

 

 

 

 

 

(H-band)

 

 

 

 

 

 

 

 

 

OUTPUT

 

1

• Operating frequency:

Top

Connect an RF power meter to

 

1.0 W

POWER

 

 

136.000 MHz (L-band)

panel

the antenna connector.

 

 

 

[POWER (LO)]

 

 

146.000 MHz (H-band)

 

 

 

 

 

 

 

 

 

 

• High/Low switch

: Low

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[POWER (HI)]

 

2

• High/Low switch

: High

 

 

 

 

 

5.0 W

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM

 

1

• Operating frequency:

Top

Connect an FM deviation meter

±4.1 kHz (W-type)*1

DEVIATION

 

 

136.000 MHz (L-band)

panel

to the

antenna

connector

±3.3 kHz (M-type)

[MOD]

 

 

146.000 MHz (H-band)

 

through the attenuator.

±2.0 kHz (N-type)*1

 

 

 

• High/Low switch

: Low

 

 

 

 

 

 

 

 

 

 

• Connect the audio generator to the

 

 

 

 

 

 

 

 

 

 

[MIC] jack and set as

 

 

 

 

 

 

 

 

 

 

 

: 1.0 kHz/150 mVrms

 

 

 

 

 

 

 

 

 

 

• Set the FM deviation meter as:

 

 

 

 

 

 

 

 

 

 

HPF

: OFF

 

 

 

 

 

 

 

 

 

 

LPF

: 20 kHz

 

 

 

 

 

 

 

 

 

 

De-emphasis

: OFF

 

 

 

 

 

 

 

 

 

 

Detector

: (P–P)/2

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DTCS WAVE

 

1

• Operating frequency:

Top

Connect an FM deviation meter

Set to flat wave

FORM

 

 

143.000 MHz (L-band)

panel

with an oscilloscope to the

form

[DTCS BAL]

 

 

160.000 MHz (H-band)

 

antenna

connector

through an

 

 

 

 

 

 

• High/Low switch

: Low

 

attenuator.

 

 

 

 

 

 

 

• No audio applied to the [MIC] jack.

 

 

 

 

 

 

 

 

 

 

• DTCS code

: 007

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1W/N-type must adjust both (W-type) and (N-type).

5 - 6

Image 16
Contents VHF FM Transceivers Ordering Parts IntroductionRepair Notes Table of Contents Section Specifications EIA/TIAMain Unit TOP View Inside ViewsBottom View Disassembly and Option Instructions Disassembly InstructionRemoving the Chassis Panel Removing the Main UnitOptional Unit Installations Circuit Description Receiver CircuitsTransmitter Circuits Power Supply Circuits Voltage Line PLL CircuitPort Allocations Output Expander IC IC10Adjustment Procedures Preparation¥ JIG cable Top view PLL Adjustment Software Adjustment TXFSoftware Adjustment Parts List Main UnitVariable Thermistor NTCCM20124AG473J-T Tantalum ECST0JY106R Chassis Unit Accessories Mechanical Parts and DisassemblyChassis Parts IC-F3GS parts Transistor and FET’S SEMI-CONDUCTOR InformationDiodes Board Layouts General and EIA/TIA Versions Except W/N-TYPEMP6 Main Unit Bottom ViewIC1 ETS/CEPT VersionMP5 VHF FI1 Parts List Disassembly InformationBC-137 Optional Desktop Charger Informasion ConvenientVoltage Diagram Board LayoutBlock Diagram Option UnitVoltage Diagram BU4066BCFVBand of ETS/CEPT version N-type DTA144EU Section Voltage Diagram Avref Vtref Toned Tonem AvccPage 32, Kamiminami, Hirano-ku, Osaka, 547-0003, Japan UHF FM Transceivers IC-F4GTIC-F4GS Preparation PLL Adjustment Software Adjustment Power supply requirement APC IC3A NJM3403AV Disassembly and Option Instructions Optional Unit Installations 2ND if and Demodulator Circuits RF signal From PLL Driver PLL Circuit Power Supply Circuits Voltage Line Resistor R132PTT Adjustment Procedures Screen Display Example DC Power Cable Connections L405 L11 Powerlo BPF T1 NJM3403AV-TE1 IC4 Resistor ERJ2GE Thermistor NTCCM1608 4LH 223KC Ceramic ECUE1H470JCQ ECEV1CA470SP Other Ceramic ECJ0EB1E471K Band MHz band MHz and H-band IC-F4GS parts DTA144 EU DTC144 EE DTC144 EU DTC144 TU LOW Band DS1FI1 440-470 MHz Band Except W/N-TYPE Icom 470-500 MHz and High Bands B5542B C308 Q19 B5688B BC-137 Optional Desktop Charger Informasion Voltage Diagram Type Type of GEN Type of GEN and EIA/TIA version NJM3403AV M1-band of GEN and EIA/TIA version G W-type of GEN Type 2SC3585 R44 Q403 2SC5107 O Band of ETS/CEPT version N-type M1 440-470 MHz-band Page 13713IZ-C1U