Icom IC-F3GS, IC-F3GT service manual Powerlo

Page 56

5-3 SOFTWARE ADJUSTMENT

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

MEASUREMENT

VALUE

 

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

REFERENCE

1

• Operating frequency:

 

Top

Loosely couple a frequnecy

400.0000 MHz A

FREQUENCY

 

400.000

MHz A

panel

counter to the antenna connec-

440.0000 MHz B

[TXF]

 

440.000

MHz B

 

tor.

470.0000 MHz C

 

 

470.000

MHz C

 

 

490.0000 MHz D, E

 

 

490.000

MHz D, E

 

 

 

 

 

• High/Low switch : Low

 

 

 

Connect the RF power meter or 50 Ω dummy load to the antenna connector.

Transmitting

OUTPUT

1

• Operating frequency:

 

Top

Connect an RF power meter to

1.0 W

 

POWER

 

415.000

MHz [EUR] of A

panel

the antenna connector.

 

 

[POWER(LO)]

 

430.000

MHz [OTHER] of A

 

 

 

 

 

 

455.000

MHz [EUR] of B

 

 

 

 

 

 

470.000

MHz [OTHER] of B

 

 

 

 

 

 

500.000

MHz C

 

 

 

 

 

 

 

 

512.000

MHz D

 

 

 

 

 

 

 

 

520.000

MHz E

 

 

 

 

 

 

 

 

• High/Low switch

: Low

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[POWER(HI)]

2

• High/Low switch

: High

 

 

4.0 W

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM

1

• Operating frequency:

 

Top

Connect an FM deviation meter

±3.9 kHz*1

DEVIATION

 

 

400.000

MHz A

panel to the antenna connector

±3.2 kHz ˜

[MOD]

 

 

440.000

MHz B

 

through the attenuator.

±1.95 kHz*2

ˆ

 

 

 

470.000

MHz C

 

 

 

 

 

 

 

490.000

MHz D, E

 

 

 

 

 

 

• High/Low switch

: Low

 

 

 

 

Connect the audio generator to the [MIC] jack and set as:

1.0kHz/150 mVrms

Set the FM deviation meter as:

 

HPF

 

: OFF

 

 

 

 

 

LPF

 

: 20 kHz

 

 

 

 

 

De-emphasis

: OFF

 

 

 

 

 

Detector

 

: (P–P)/2

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

DTCS WAVE

1 • Operating frequency:

Top Connect an FM deviation meter

Set to flat wave

FORM

 

430.000 MHz A

panel with an oscilloscope to the

form

[DTCS BAL]

 

470.000 MHz B

antenna connector through an

 

 

 

 

 

500.000 MHz C

attenuator.

 

 

 

 

 

512.000 MHz D

 

 

 

 

 

 

520.000 MHz E

 

 

 

 

 

• High/Low switch

: Low

 

 

 

 

 

 

 

 

 

 

• No audio applied to the [MIC] jack.

 

 

 

 

 

• DTCS code

: 007

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

*1, *2W/N-type must be adjusted both *1 and *2 on the FM DEVIATION ADJUSTMENT.

 

A: 400–430 MHz

B: 440–470 MHz

C: 470–500 MHz

D: 490–512 MHz

E: 490–520 MHz

ˆ: N-type

: W-type

˜: M-type

 

 

5 - 6

Image 56
Contents VHF FM Transceivers Repair Notes IntroductionOrdering Parts Table of Contents Section Specifications EIA/TIABottom View Inside ViewsMain Unit TOP View Disassembly and Option Instructions Disassembly InstructionRemoving the Chassis Panel Removing the Main UnitOptional Unit Installations Circuit Description Receiver CircuitsTransmitter Circuits Power Supply Circuits Voltage Line PLL CircuitPort Allocations Output Expander IC IC10Adjustment Procedures Preparation¥ JIG cable Top view PLL Adjustment Software Adjustment TXFSoftware Adjustment Parts List Main UnitVariable Thermistor NTCCM20124AG473J-T Tantalum ECST0JY106R Chassis Unit Chassis Parts Mechanical Parts and DisassemblyAccessories IC-F3GS parts Diodes SEMI-CONDUCTOR InformationTransistor and FET’S Board Layouts General and EIA/TIA Versions Except W/N-TYPEMP6 Main Unit Bottom ViewIC1 ETS/CEPT VersionMP5 VHF FI1 Parts List Disassembly InformationBC-137 Optional Desktop Charger Informasion ConvenientVoltage Diagram Board LayoutBlock Diagram Option UnitVoltage Diagram BU4066BCFVBand of ETS/CEPT version N-type DTA144EU Section Voltage Diagram Avref Vtref Toned Tonem AvccPage 32, Kamiminami, Hirano-ku, Osaka, 547-0003, Japan UHF FM Transceivers IC-F4GTIC-F4GS Preparation PLL Adjustment Software Adjustment Power supply requirement APC IC3A NJM3403AV Disassembly and Option Instructions Optional Unit Installations 2ND if and Demodulator Circuits RF signal From PLL Driver PLL Circuit Power Supply Circuits Voltage Line Resistor R132PTT Adjustment Procedures Screen Display Example DC Power Cable Connections L405 L11 Powerlo BPF T1 NJM3403AV-TE1 IC4 Resistor ERJ2GE Thermistor NTCCM1608 4LH 223KC Ceramic ECUE1H470JCQ ECEV1CA470SP Other Ceramic ECJ0EB1E471K Band MHz band MHz and H-band IC-F4GS parts DTA144 EU DTC144 EE DTC144 EU DTC144 TU LOW Band DS1FI1 440-470 MHz Band Except W/N-TYPE Icom 470-500 MHz and High Bands B5542B C308 Q19 B5688B BC-137 Optional Desktop Charger Informasion Voltage Diagram Type Type of GEN Type of GEN and EIA/TIA version NJM3403AV M1-band of GEN and EIA/TIA version G W-type of GEN Type 2SC3585 R44 Q403 2SC5107 O Band of ETS/CEPT version N-type M1 440-470 MHz-band Page 13713IZ-C1U