ADJUSTMENT MODE ADJUSTMENTS (Continued)
The following adjustment must be performed at “ADJUSTMENT MODE”.
|
|
|
| MEASUREMENT |
| ADJUSTMENT | ||||
ADJUSTMENT | ADJUSTMENT CONDITION | VALUE | POINT | |||||||
|
|
| ||||||||
|
|
|
|
| ||||||
|
|
|
| UNIT | LOCATION |
| UNIT | ADJUST | ||
|
|
|
|
|
|
|
| |||
RF | 11 | • Displayed frequency : | AF | Connect a DC volt- | Maximum voltage | Top | [DIAL] | |||
TRACKING |
| (TM ch.) | 430.100 MHz |
| meter or | oscillo |
| panel |
| |
|
| • Connect the SSG to the antenna |
| scope to the IC151, |
|
|
| |||
|
| connector and set as: |
| pin 12 (“SD” line). |
|
|
| |||
|
| Level | : 0.5 µV* |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
| Modulation : 1 kHz |
|
|
|
|
|
| ||
|
| Deviation | : ± 3.5 kHz |
|
|
|
|
|
| |
|
| • Receiving |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
| 12 | • Displayed frequency : |
|
|
| Maximum voltage |
| [DIAL] | ||
|
| (TH ch.) | 499.100 MHz |
|
|
|
|
|
| |
|
| • Receiving |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
| 13 | • Displayed frequency : |
|
|
| Maximum voltage |
| [DIAL] | ||
|
| (TL ch.) | 450.100 MHz |
|
|
|
|
|
| |
|
| • Receiving |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
| 14 | • Displayed frequency : |
|
|
| Maximum voltage |
| [DIAL] | ||
|
| (TH ch.) | 569.100 MHz |
|
|
|
|
|
| |
|
| • Receiving |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
| 15 | • Displayed frequency : |
|
|
| Maximum voltage |
| [DIAL] | ||
|
| (TL ch.) | 630.100 MHz |
|
|
|
|
|
| |
|
| • Set the SSG as: |
|
|
|
|
|
| ||
|
| Level | : 1 µV* |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
| • Receiving |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
| 16 | • Displayed frequency : |
|
|
| Maximum voltage |
| [DIAL] | ||
|
| (TH ch.) | 900.100 MHz |
|
|
|
|
|
| |
|
| • Set the SSG as: |
|
|
|
|
|
| ||
|
| Level | : 3.2 µV* |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
| • Receiving |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |||
|
| CONVENIENT: The “RF TRACKING” can be adjusted automatically. |
|
| ||||||
|
|
| q: Set the Displayed frequency (TL ch.) | 30.100 MHz |
|
| ||||
|
|
| w: Connect the SSG to the antenna connector and set as: |
|
| |||||
|
|
| Level | : 0.5 µV* |
|
| ||||
|
|
| Modulation | : 1 kHz |
|
|
|
| ||
|
|
| Deviation | : ± 3.5 kHz |
|
|
|
| ||
|
|
| e: Receiving |
|
|
|
|
|
| |
|
|
| r: Push the [BAND] key to start tuning, automatically. |
|
| |||||
|
|
| t: Repeat |
|
| |||||
|
|
|
|
|
|
|
|
|
|
*This output level of the standard signal generator (SSG) is indicated as SSG’s open circuit.
When adjusting by automatically, must change the SSG’s level which is depened on adjustment frequencies as shown above.
5 - 13