Parker Hannifin N dimensions Solenoid Characteristics Chart, Continuous Duty Pilots

Page 11

Catalog 0600P-10/USA

“N” Series Valves

Technical Information

Solenoid Characteristics

 

 

Solenoid Characteristics Chart

Voltage Range +10/-15% of Nominal

3/8" & 3/4" Basic – L-Pilot

Voltage/

Amps

Amps

Resistance

 

Insulation

Cycles

Inrush

Holding

Ohms

Watts

Class

 

 

 

 

 

 

120/60VAC

.29

.18

122

12

B

 

 

 

 

 

 

110/50VAC

.21

.14

122

12

B

 

 

 

 

 

 

240/60VAC

.18

.12

610

12

B

 

 

 

 

 

 

24/60VAC

1.6

1.0

4.5

9.5

B

 

 

 

 

 

 

24/50VAC

1.2

.75

6.4

9.5

B

 

 

 

 

 

 

  6VDC

1.4

4.5

7.6

B

 

 

 

 

 

 

12VDC

.66

17.7

9

B

 

 

 

 

 

 

24VDC

.32

71

9

B

 

 

 

 

 

 

48VDC

.22

216

11

B

 

 

 

 

 

 

Continuous Duty Pilots

Continuous duty pilots are designed for applications where cycling is infrequent and the pilot is to be energized for indefinite periods of time . . . hours, days or weeks. Typical uses include fail-safe or emergency shutdown circuits where the pilot is to be energized and the valve open as long as the main control is “live” in order to shut off air to equipment in the event of power failure.

The Continuous duty pilot operates satisfactorily in ambient temperatures up to 125°F, even when continuously energized and without the benefit of the cooling air which normally flows through the pilot during frequent cycling. Under certain conditions, satisfactory operation may be obtained at ambient temperatures above 125°F. CONSULT FACTORY.

Incorporating the performance-proven design features of the standard

1-1/4" Basic – P-Pilot

Voltage/

Amps

Amps

Resistance

 

Insulation

Cycles

Inrush

Holding

Ohms

Watts

Class

 

 

 

 

 

 

120/60VAC

.46

.25

35

18.5

B

 

 

 

 

 

 

110/50VAC

.36

.19

48

12

B

 

 

 

 

 

 

230/60VAC

.26

.15

125

19.5

B

 

 

 

 

 

 

220/50VAC

.20

.11

191

15

B

 

 

 

 

 

 

24/60VAC

2.3

1.4

1.3

20

B

 

 

 

 

 

 

24/50VAC

1.6

.9

2.1

12

B

 

 

 

 

 

 

12VDC

.7

17

8

B

 

 

 

 

 

 

24VDC

.33

68

8

B

 

 

 

 

 

 

48VDC

.16

275

7.5

B

 

 

 

 

 

 

NOTE:Continuous duty type service is for applications where pilot valve is energized more than ten (10) minutes.

L-Pilot, the continuous duty pilot utilizes a bullet-shaped stem on the upper end of the plunger.

This bullet-shaped stem, seating in a high-temperature rubber o-ring, provides both a bubble-tight seal and

positive release.

Continuous Duty

Pilot

M

Hazardous Duty Solenoid Listing

Valves with solenoid operators designed for hazardous locations are UL & CSA Approved as follows:

National Electric

 

NEMA

Code

Ambient Conditions

Classification

 

 

 

Class I Div. 1

Ethyl, Ether, Etc. Gases &

VII (7)

Group C

Vapors

 

 

 

 

Class I Div. 1

Gasoline, Etc. Gases & Vapors

VII (7)

Group D

 

 

 

 

 

Class I Div. 2

Butadiene, Etc., Liquid, Fluid

 

or Vapor Normally Contained,

VII (7)

Group B

or Atmosphere Ventilated

 

 

 

 

 

 

Class II Div. 1

Metal Dust

IX (9)

Group E

 

 

 

 

 

Class II Div. 1

Coal, Coke, Carbon Black

IX (9)

Group F

Dust

 

 

 

 

Class II Div. 1

Flour, Starch, Grain Dust

IX (9)

Group G

 

 

 

 

 

See Article 500 – Hazardous (Classified) Locations, National Electric Code.

M11Parker Hannifin Corporation

Pneumatic Division

Richland, Michigan

www.parker.com/pneumatics

Image 11
Contents Series Single Remote Pilot Way, 2-Position, SignalSingle Solenoid Way, 2-PositionPort Sizes SpecificationsFeatures Flow3/4 Body Size Single Solenoid Normally Closed Normally OpenCommon Part Numbers Inline Poppet Valve Solenoid Operated Way, 2-PositionWay In/Cyl  Exh Normally Open Ports Single Remote Pilot Normally Closed Normally OpenCommon Part Numbers 4 1-1/2Model Number Index Inline Poppet Valve Solenoid Operated Series 3/8, 3/4 & 1-1/4 Body Sizes Solenoid ‘L’ PilotModel Number Index Solenoid & Remote Pilot Operated Valve Series 1-1/4 Body Sizes Solenoid Hi-Flow ‘P’ PilotSeries 3/8, 3/4 & 1-1/4 Body Sizes Remote Pilot Solenoid Valves External Supply Life Expectancy Temperature RatingInstallation SelectionTechnical Information Wiring ConnectionsSolenoid Configurations Automotive ConnectionsHazardous Duty Solenoid Listing Solenoid Characteristics ChartTechnical Information Solenoid Characteristics Continuous Duty PilotsTechnical Information Solenoid Pilot & Parts List Nema 1 Replacement PilotsParts List Technical Information Solenoid Pilot & Parts List Nema 4, 7 Voltage Code 49 Override & Indicator Lights 120VAC OnlyTechnical Information Heavy Duty P-Pilot Valve Heavy Duty P-PilotVoltage Coil Code 60Hz 50Hz Leads Coils for L-Pilot Operated ValvesCoils for P-Pilot Operated Valves Technical Information Coil InformationTime Delay Modules Inline Poppet Valves 3/8 & 3/4 Time Delay Modules ProvideSetting Selector for Desired Function How to Order KitsNormally Open DimensionsService Kits Normally Closed200 226 110 137 KeyInch mm 16UNC Deep 163 189Key 4 Valve Description Dimensions Single Solenoid Internal Pilot 1-1/4 Basic BodyDimensions Normally Closed Key Body10.45 265 116 Key  4 Body Inch13 UNC 229Key Valve 4 Valve Description Dimensions Remote OperatedKey  Body 4 Body Inch  mm Key Valve 4 Valve Part Body 4 Body Key Global Pneumatics, Warning, Offer of Sale Global PneumaticsPhosphate ester and di-ester lubricants Safety GuideInstruction sheets supplied for maximum pressure ratings Routine Maintenance Issues Product Assembly and Installation InstructionsOffer of Sale