Parker Hannifin dimensions Normally Closed, Dimensions, Normally Open, Service Kits

Page 17

Catalog 0600P-10/USA

“N” Series Valves

Dimensions - Single Solenoid

Internal Pilot - 3/8" & 3/4" Basic Body

 

 

A

B

Exhaust

 

 

Pressure

A

D C

Top view indicates flow through 3-Way

 

valve with coil de-energized.

 

D

NOTE: For normal valve operation, override

F

 

E

must be in “out” position.

 

Normally Closed

13

12

3*

11*

2

4*

1

5

 

CYL.

IN

7*

6

 

14

8

10

9

 

On 2-Way Valve This

Port Is Plugged

G

1/2 NPT

Conduit

Connection

H100-60

H175-12

K183-001*

H100-59

H175-12

R P

H

EXH

J

N

K

 

M

L Travel

AB

A

D C

D

A

E

Dimensions

Key

3/8" Body

  3/4" Body

Inch

mm

Inch

mm

 

A

1.56

40

2.13

54

B

1.50

38

1.94

49

C

1.81

46

1.34

34

D

.56

14

.56

14

E

3/8-16UNC

3/8-16UNC

7/16" deep

9/16" deep

 

F

1.75

44

2.25

57

G

1.50

38

1.50

38

H

5.92

150

7.14

181

J

3.19

81

3.75

95

K

1.88

47

2.44

62

L

.11

3

.16

4

M

.50

13

.50

13

N

1.44

37

1.78

45

P

7.36

196

8.58

218

Q

2.31

59

3.09

84

R

7.92

201

8.83

224

Normally Open

13

12

 

11*

On 2-Way Valve This

Port Is Plugged

G

1/2 NPT

Conduit

Connection

H100-60

H175-12

K183-001* H100-59

Service Kits

Include all parts normally required for in-service maintenance:

3/8"

Basic Valve with standard

 

 

service L-Pilots

K352 076

3/8"

Basic Valve with continuous

3*

2

4*

R P

H 175-12

duty L-Pilots

K352 276

5

 

CYL.

IN

1A

6

 

7*

8

10A

9

 

 

EXH

H

 

 

Q

 

J

 

K

 

 

M

3/4"

Basic Valve with standard

 

 

service L-Pilots

K352 077

3/4"

Basic Valve with continuous

 

duty L-Pilots

K352 277

L Travel

Key

3/8" Valve

3/4" Valve

Description

 

1/2" Tap

 

 

K053 075

 

 

 

 

1

3/8" Tap

3/4" Tap

Body (N.C.)

K053 022

K053 076

 

 

 

1/2" Tap

1" Tap

 

 

K053 023

K053 220

 

 

3/4" Tap

 

 

K053 077

 

 

 

 

1A

3/8" Tap

3/4" Tap

Body (N.O.)

K053 025

K053 078

 

 

 

1/2" Tap

1" Tap

 

 

K053 026

K053 218

 

2

K212 001

K212 002

Upper Piston Assy

3*

H136 48

H137 28

Seal

4*

H145 10

H136 76

U-Cup (3/8), O-Ring (3/4)

Key

3/8" Valve

3/4" Valve

Description

5

K493 002

K493 009

Stem

6

K202 001

K202 002

Lower Piston Assy.

7*

H145 09

H136 76

U-Cup (3/8), O-Ring (3/4)

8

H178 11

H178 13

Washer (2)

9

H063 26

H063 32

Stop Nut (2)

10

K103 035

K103 053

Bottom Cap (N.C.)

10A

K092 020

K092 034

Bottom Cap Assy. (N.O.)

11*

K183 049

K183 057

Gasket

12

K473 014

K473 015

Spring

13

K563 015

K563 017

Adapter

14*

K41RB72121

K41RB72221

O-Ring

* Parts included in seal kit

M17Parker Hannifin Corporation

Pneumatic Division

Richland, Michigan

www.parker.com/pneumatics

Image 17
Contents Series Single Solenoid Way, 2-Position, SignalWay, 2-Position Single Remote PilotFeatures SpecificationsFlow Port SizesCommon Part Numbers Inline Poppet Valve Solenoid Operated Single Solenoid Normally Closed Normally OpenWay, 2-Position 3/4 Body SizeCommon Part Numbers Single Remote Pilot Normally Closed Normally Open4 1-1/2 Way In/Cyl  Exh Normally Open PortsModel Number Index Inline Poppet Valve Solenoid Operated Series 3/8, 3/4 & 1-1/4 Body Sizes Solenoid ‘L’ PilotModel Number Index Solenoid & Remote Pilot Operated Valve Series 1-1/4 Body Sizes Solenoid Hi-Flow ‘P’ PilotSeries 3/8, 3/4 & 1-1/4 Body Sizes Remote Pilot Solenoid Valves External Supply Installation Temperature RatingSelection Life ExpectancySolenoid Configurations Wiring ConnectionsAutomotive Connections Technical InformationTechnical Information Solenoid Characteristics Solenoid Characteristics ChartContinuous Duty Pilots Hazardous Duty Solenoid ListingTechnical Information Solenoid Pilot & Parts List Nema 1 Replacement PilotsParts List Technical Information Solenoid Pilot & Parts List Nema 4, 7 Technical Information Heavy Duty P-Pilot Valve Override & Indicator Lights 120VAC OnlyHeavy Duty P-Pilot Voltage Code 49Coils for P-Pilot Operated Valves Coils for L-Pilot Operated ValvesTechnical Information Coil Information Voltage Coil Code 60Hz 50Hz LeadsSetting Selector for Desired Function Time Delay Modules ProvideHow to Order Kits Time Delay Modules Inline Poppet Valves 3/8 & 3/4Service Kits DimensionsNormally Closed Normally OpenInch mm Key16UNC Deep 163 189 200 226 110 137Dimensions Normally Closed Dimensions Single Solenoid Internal Pilot 1-1/4 Basic BodyKey Body Key 4 Valve Description13 UNC Key  4 Body Inch229 10.45 265 116Key Valve 4 Valve Description Dimensions Remote OperatedKey  Body 4 Body Inch  mm Key Valve 4 Valve Part Body 4 Body Key Global Pneumatics, Warning, Offer of Sale Global PneumaticsPhosphate ester and di-ester lubricants Safety GuideInstruction sheets supplied for maximum pressure ratings Routine Maintenance Issues Product Assembly and Installation InstructionsOffer of Sale