SECTION 5 - MAINTENANCE
The following maintenance schedule is recommended:
Action |
|
| Description |
| Frequency |
Visual inspection |
| Inspect the antenna, cables and |
| Every 6 months | |
|
| connections. Ensure that the cable is |
|
| |
|
| attached properly and the unit has not been |
|
| |
|
| damaged. |
|
| |
Performance |
| Verify that the system is operating by |
| Every year | |
test |
| using the training mode with a training |
|
| |
|
| beacon |
|
| |
Clean exterior |
| Using a mild, sudsy solution such as |
| As needed | |
|
| dishwashing liquid, wipe the surface of |
|
| |
|
| the |
|
| |
|
| remove film, salt and sand |
|
| |
APPENDIX A - SPECIFICATIONS |
| ||||
|
|
|
|
| |
General |
|
|
|
| |
Carrier frequency |
| 121.5 MHz or 121.65 MHz, user selectable | |||
Sensitivity |
| <0.2 µV (at antenna output) |
| ||
VHF antenna |
| Flexible monopole |
| ||
Modulation |
| Swept tone |
| ||
Electrical input power | +10.5 V to +28 V DC, 120 mA average, 400 mA | ||||
|
|
| maximum |
| |
Alert methods |
|
|
|
| |
|
|
| Bright red flashing led |
| |
|
|
| Loud audible alarm (≈70dBA @ 1m) | ||
|
|
| External speaker connection (8v maximum) | ||
|
|
| Relay contacts: normally open (2 A/30 V | ||
|
|
| maximum) |
| |
Regulation conformity |
|
|
| ||
Safety |
| IEC 60945, EN50371 |
| ||
EMI/EMC |
| IEC 60945 |
| ||
RoHS/WEEE |
| European Directive 2002/95/EC |
| ||
Physical |
|
|
|
| |
Dimensions |
| 5.3” X 3.7” X 1.5” (13.46 X 9.40 X 3.81cm) | |||
Weather resistance |
| IP65 (when included monopole antenna is | |||
|
|
| correctly installed) |
| |
Operating temperature |
| ||||
Storage temperature |
| ||||
Weight |
| 0.8 lbs (362.87 g) |
|
| 9 |