ACR Electronics ARX-50, Y1-03-0229C Installation, Location selection, Ship’s power requirements

Page 6

Location selection

Choose a dry, clean surface to install the ARX-50, giving consideration to the importance of the location. The user must be able to see the visual alarm and hear the audible alarm.

CAUTION: When using the included antenna, the ARX-50 must be mounted vertically and the antenna must not be within 0.5 m of a metal panel or other metal objects.

Ship’s power requirements

The ARX-50 accepts ship’s power supply in the range of +10.5 to +28 V DC. A two-wire connection (ground negative) is required that is capable of supplying 120 mA average and up to 400 mA under an alarm condition at +10.5 to +28 V DC.

SECTION 3 - INSTALLATION

Mount the bracket

After selecting the location, hold the ARX-50 bracket in position and use as a template to mark where the screws will be located.

CAUTION: When mounting to a wall, avoid mounting to metal.

Pre-drill holes of a smaller diameter than the screws, if appropriate for the material that the bracket will be attached to.

Holding the bracket in place, screw the four supplied screws through the openings in the bracket to the mounting material, securing the screws tightly enough to allow for vibration, yet loose enough to avoid cracking the case.

Snap the ARX-50 into its bracket vertically, antenna skyward. Double-check that the ARX-50 is seated and secure by manually testing it for stability.

Install the monopole antenna

Install the monopole antenna on the ARX-50 via the BNC connector. The open end of the antenna is attached to the connector by a clockwise motion. The antenna snaps into place, locking it.

CAUTION: Proper installation of the monopole antenna is required to seal the ARX-50. If any antenna other than the included monopole antenna is used, the unit may not seal properly.

Y1-03-0229C

5

Image 6
Contents Y1-03-0229C Y1-03-0229C Table of Contents Unpacking the ARX-50 Preparing to InstallHOW the ARX-50 Works QuantityY1-03-0229C Install the monopole antenna InstallationShip’s power requirements Location selectionOperation Choose Alarm mode or Monitor mode Turn on the ARX-50Training mode Activation and alarm indicatorsMaintenance Appendix a SpecificationsLimited Warranty Appendix B AccessoriesAppendix C WARRANTY, Useful Life POLICY, Notices Description ACR Part NumberFCC Compliance Statement EC Declaration of Conformity