Mustang Survival MD3083, MD3084, MD3082, MD3081 Inflatable PFD Safety Accessories, Help Position

Page 25

Your will-to-live does make a difference!

5)If there is more than one person in the water, huddling is recommended while waiting to be rescued. This action tends to reduce the rate of heat loss and thus increase the survival time.

Figure 18

HELP Position

EACH OF THESE DEVICES IS INTENDED TO HELP YOU SAVE YOUR OWN LIFE

For your Inflatable PFD to function properly, follow these suggestions to verify that it fits, floats, and remains in good condition.

1)Check the inflation mechanism status indicators before each use.

2)Get in the habit of re-arming the inflation mechanism right after each inflation.

3)Try your wearable Inflatable PFD on and adjust it until it fits comfortably in and out of the water.

4)Mark your Inflatable PFD with your name if you are the only wearer.

5)Do not alter your Inflatable PFD. If it doesn’t fit properly, get one that does. An altered device is no longer Coast Guard approved.

6)Your Inflatable PFD is not intended for use as a fender or kneeling pad.

7)If your Inflatable PFD is wet, allow it to dry thoroughly before storing it. Store it in a well-ventilated area.

8)Do not dry your Inflatable PFD in front of a radiator or other source of direct heat.

Inflatable PFD Safety Accessories

Inflatable PFD Owner’s Manual

22

Image 25
Contents MD3081 Inflatable PFD Page Contents Mandatory Carriage Requirements Instructions for USE What is AN Inflatable PFD?Congratulations on your Inflatable PFD purchase Component Inspection InstructionsOral-inflation dust cap is in the stowed position Readiness ChecklistSizing and Fit Donning InstructionsInflating Your Inflatable PFD Automatic Backup Inflation MD3083 and MD3084Manual Inflation InformationPage Your device is ready to be repacked see Repacking p Deflating the Inflatable PFDRe-arming Your PFD MD3081 and MD3082 Usage Below FreezingImportant Follow instructions in the exact sequence below MD3081 and MD3082 Manual Inflator Re-arming Your PFD MD3083 and MD3084 CO2 Removed prior to re-armingTop SolidSensor RingRepacking Sailing Harness Care and Maintenance Instructions Is Your PFD in Good and Serviceable CONDITION?Tether WebbingPage WHY are Pfds Required Safety EQUIPMENT? HOW and WHY to Test Your PFDPut on the Inflatable PFD Models MD3083 and MD3084HOW do YOU Test Your PFD Using the Manual INFLATOR? HOW do YOU Test Your PFD Using the Oral INFLATOR?Hypothermia Wear Your PFDHow hypothermia affects most adults Your will-to-live does make a difference Inflatable PFD Safety AccessoriesHelp Position Do not Attach PFDs to Your Boat Additional InformationPage Mustangsurvival.com We save lives for a living