Mustang Survival MD3084, MD3083, MD3082, MD3081 manual Repacking

Page 16

12)Refold the Inflatable PFD in accordance with the Repacking section (p. 13).

YOUR INFLATABLE PFD (MD3083 and MD3084) IS NOW READY FOR MANUAL USE WITH AUTOMATIC BACKUP

Figure 12

MD3083 and MD3084 Automatic Inflator

Tab

Cylinder

 

Piercing

 

Pin

 

Service

 

Indicator

1/8 Turn

Groove

Pull-cord

Repacking

Gently squeeze the Inflatable PFD until all air or gas has been expelled (Fig. 6). Do not wring or twist the Inflatable PFD. Put the inflation tube dust cap back in its stowed position on the oral inflation tube (Fig. 7).

NOTE: Before following the repacking sequence, be sure to properly re-arm your Inflatable PFD.

1)Fold side (A) inward along the full length of the dotted line (Fig. 14).

2)Fold lapel (B) inward along dotted lines. Fasten along the full length of the Velcro™. Ensure that the Inflatable PFD is tucked under the Velcro™ strip.

3)Repeat steps 1 and 2 with side (C) and lapel (D). Your Inflatable PFD will look as illustrated in Fig. 15.

4)Fold down the collar (E) along the dotted line (Fig. 15).

5)Fold the cover (F) up over the collar and fasten with (3) Velcro™ tabs (Fig. 15 inset).

6)Ensure the pull-tab is on the outside of the folded Inflatable PFD. Fig. 16 depicts a correctly folded Inflatable PFD.

Note: Ensure that all Velcro™ strips and tabs are fastened.

13

Inflatable PFD Owner’s Manual

Image 16
Contents MD3081 Inflatable PFD Page Contents Mandatory Carriage Requirements What is AN Inflatable PFD? Instructions for USECongratulations on your Inflatable PFD purchase Component Inspection InstructionsReadiness Checklist Oral-inflation dust cap is in the stowed positionDonning Instructions Sizing and FitAutomatic Backup Inflation MD3083 and MD3084 Inflating Your Inflatable PFDManual Inflation InformationPage Deflating the Inflatable PFD Your device is ready to be repacked see Repacking pRe-arming Your PFD MD3081 and MD3082 Usage Below FreezingImportant Follow instructions in the exact sequence below MD3081 and MD3082 Manual Inflator Re-arming Your PFD MD3083 and MD3084 Removed prior to re-arming CO2Solid TopSensor RingRepacking Sailing Harness Is Your PFD in Good and Serviceable CONDITION? Care and Maintenance InstructionsTether WebbingPage HOW and WHY to Test Your PFD WHY are Pfds Required Safety EQUIPMENT?Models MD3083 and MD3084 Put on the Inflatable PFDHOW do YOU Test Your PFD Using the Oral INFLATOR? HOW do YOU Test Your PFD Using the Manual INFLATOR?Wear Your PFD HypothermiaHow hypothermia affects most adults Your will-to-live does make a difference Inflatable PFD Safety AccessoriesHelp Position Additional Information Do not Attach PFDs to Your BoatPage We save lives for a living Mustangsurvival.com