Raymarine ST40 manual Intermediate calibration, Dealer calibration

Page 32

Chapter 4: Calibration

23

4.3 Intermediate calibration

Intermediate calibration enables you to:

Check the instrument software version.

Check and if necessary set, the instrument status - either MASTR (master) or REPTR (repeater).

Follow the procedure in the Intermediate calibration flow diagram.

INTERMEDIATE CALIBRATION

During normal operation

hold down

and

for approximately 4 seconds

Software

 

 

version

 

Note:

 

 

If there is no key activity when

 

 

the Software version screen

 

 

is displayed, calibration will

 

 

time out to normal operation

 

 

after 5 seconds,

Instrument status

CAL

To save your settings and return to normal operation from either screen,

hold down

and

for approximately 2 seconds

 

 

D4615-2

4.4 Dealer calibration

Dealer calibration enables you to set:

User calibration on/off.

Boat show mode on/off.

Dealer calibration also gives access to the Factory defaults screen. This enables you to reapply the factory settings if you want to reset the instrument to a known operating condition.

Follow the procedure in the Dealer calibration flow diagram.

Image 32
Contents Distributed by ST40 Speed Instrument Copyright Raymarine Limited Handbook information Important informationEMC conformance ST40 Speed Instrument Owner’s Handbook Contents Calibration Preface Parts supplied Speed transducer Supplied with bung not illustratedIntroduction Operating proceduresOperation Normal Operation Adjusting display backlighting and contrast Adjust BacklightingST40 Speed Instrument Owner’s Handbook Servicing and safety Maintenance and Fault FindingMaintenance Fault finding Low battery No speed or water temperature informationNo speed Information But water Temperature Information is Display blankAssistance EMC installation guidelines InstallationPlanning your installation Connections to Other Equipment Tools requiredSuppression Ferrites Hull material Transducer type Site requirementsTransducer Transducer siting Instrument ProceduresFitting transducer Connections to the instrument Running transducer cableStand-alone connections Fitting the instrument SeaTalk connectionsCut hole Desktop Mounting Bracket Screw stud into instrumentCalibration requirement ST40 Speed Instrument Owner’s Handbook EMC conformance CalibrationUser calibration User Calibration Intermediate calibration Dealer calibrationDealer Calibration Instrument Specification ST40 Speed Instrument Owner’s Handbook Response GlossaryCal factor ST40 Speed Instrument Owner’s Handbook Index EMCST40 Speed Instrument Owner’s Handbook ST40 Instrument Template Page Limited Warranty Certificate Warranty LimitationsFactory Service Centers United States of America UK, Europe, Middle East, Far East