Installation Instructions (cont'd)
2. The convertible element is located behind the lower access
panel of the water heater. Remove the two screws securing the accesspanel, and remove panel.
NOTE: Whether or not the dement conversion is made the
model rating plate must be marked.' Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower accesspanel.
Necessary element conversion parts are located in a small bag
contained within the electrical junction box on top of the water heater.
CONVERSION PARTS
BUSS BAR
1.Before beginning the conversion turn "OFF" electric power supply to the water heater.
_,WARNING
HAZARD OF ELECTRICAL SHOCK! Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned
"OFF". FAILURE TO DO THIS COULD RESULT IN
DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
3. Open the flap of insulation to expose the opening.
4, Lower Element: Lift out the tab as shown to unclip the ter- minal cover from the thermostat, The terminal cover can be
removed from the thermostat.
!..ift out tab to _lIp
termF_d c_er from
t_'mo_
JACg,ET
TERMINAl- COVER
POINTHOLDITIN
PLACE.
LOVVER THERMOSTAT
11