Kenmore 153.31206 Installation Instructions contd, Facts to Consider About the Location, Electric

Page 7

Installation Instructions (cont'd)

Facts to Consider About the Location

You should carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most

economical use of the appliance. This water heater is not intend- ed for outdoor installation.

Whether replacing an old water heater or putting the water

heater in a new location, the following critical points must be observed.

The location selected should be indoors as close to and as cen-

tralized with the water piping system as possible. This water h eater, as well as all water heaters, will eventually leak. Do not install without adequate drainage provisions where water flow will cause damage,

Facts to Consider About the Convertible Lower Element

The Upper Element (if a double element model), is a conven- tional 3800 watt element which only operates at its rated wattage on 240 volts. (See rating plate on water heater).

The Lower Element (if a double dement model) of the water heater can be converted from operation at 3800 watts to 5500 watts on a 240 volt system.

Read and follow water heater warnings and instructions.If after reading these instructions in this manual, if you do not under- stand any portion, call Sears Service Center.

AWARNING

Before making tbe conversion to 5500 watts, check the

_,CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a man- ner that if the tank or any connections should leak, the flow of water will not cause damage to the structure.

When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain

pans are available at your local Sears stores. Such a drain pan must be piped to an adequate drain. Under no cir- cumstances is tbe manufacturer or Sears to be held

liable for any water damage in connection with this water beater.

_, CAUTION

INSTALLATION IN RESIDENTIAL GARAGES: The water heater must be located and/or protected so it is

not subject to physical damage by a moving vehicle.

The location selection must provide adequate clearances for servicing and proper operation of the water heater.

(I)power supply...must be 240 volts, (2) wiring...10 gauge AWG, Type TW_ 60C or equivalent, and (3) Circuit breakers or fus ng capable of 30 amp loading. Also, the installation must conform with this manual local codes i and electr c ut ty rules. Failure to comply can result in i

DAMAGE.DEATH,SERIOUS BODILY INJURY, OR PROPERTY

ELECTRIC 1

NOTE: Whether or not the element conversion is made the model rating plate must be marked. Using a hardpoint ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower accesspanel.

Image 7
Contents Economizer TM Power Miser TM Model NOSPower Miser TM Model no For Potable Water Heating onlyAwarning Safety PrecautionsOUS Bodily INJURY, or Property Damage Contents Preparing for the New Installation Product SpecificationsCustomer Responsibilities Materials Needed Materials and Basic Tools NeededBasic Tools Heater Installation InstructionsElectric Installation Instructions contdFacts to Consider About the Location Facts to Consider About the Convertible Lower ElementWater Piping ConnectorsvalveTemperature-Pressure Relief Valve Installation InstructionsContd Filling the Water Heater Temperature-Pressure Relief Valve Optional LocationConverting the Lower Element Conversion Parts Buss BAR Propertydamage Converting the Lower Element contdINJURY, or Property Damage BOX Wiring DiagramsWiring Installation Instructions contdCold Installation Instructions contdModel Rating Plate Adjustable Lower Thermostat Dual Element Models only Service and AdjustmentTemperature Regulation Temperature SettingsLower Thermostat Service and Adjustment contdThermostat Adjustments Upper ThermostatOUS Bodily INJUR, or Property Damage Service AdjustmentTemperature-Pressure Relief Valve Operation DrainingElement Cleaning Replacement Service and Adjustment contdAwarning Service and Adjustment contd Service Drain Valve Washer ReplacementBY.PASS Troubleshooting GuideStart Up Conditions Strange SoundsRumbling Noise High Temperature Shut OFF SystemSmelly Water AIR in HOT Water FaucetsNot Enough or no HOT Water Troubleshooting Guide contdWater is TOO HOT Leakage Checkpoints Parts Order List TemFeramre-Preure Relief Valce Parts Order List contdList PartsModel Number Name of Part Partnumber Partdescription Page Warranty Sears Installation Policy WarrantyAbout Your Warranty Sears Installation Warranty