6.For Control Unit RCU-014:

a)While pressing and holding down the [HL OFF] key, press the [MENU] key five times.

b)Press the [0] key to show the INITIALIZE menu.

For Control Unit RCU-015:

See the procedure on the next page for how to show the INITIALIZE menu.

[INITIALIZE]

1BACK

2[ECHO ADJ]

3[SCANNER]

4[INSTALLATION]

5[OWN SHIP INFO]

6[ARP PRESET]

7[NETWORK]

8[OTHER]

INITIALIZE menu

7.RCU-014:Press the [2] key to open the ECHO ADJ menu.

RCU-015:Choose 2 ECHO ADJ and then push the thumbwheel.

[ECHO ADJ]

1BACK

2CABLE ATT ADJ AUTO/MANUAL 30

3HD ALIGN 000.0°

4TIMING ADJ

0

5MBS 0

6DEFAULT ANT HEIGHT 5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7NEAR STC CURVE 2/2.5/3/3.5/4.2

8MID STC CURVE

3/4/5/6

9FAR STC CURVE 6/7/8

0RING SUPPRESSION 0

ECHO ADJ menu

8.RCU-014:Press the [3] key to choose HD ALIGN.

RCU-015:Choose 3 HD ALIGN and then push the thumbwheel.

9.RCU-014:Key in the bearing difference. The setting range is 0 to 359.9(°).

RCU-015:Spin the thumbwheel to set the bearing difference and then push the thumbwheel. The setting range is 0 to 359.9(°).

10.Confirm that the target echo is displayed at correct bearing on the screen and then push the thumbwheel.

11.RCU-014:Press the [MENU] key to finish. RCU-015:Left-click the MENU box to finish.

3-3

Image 45
Contents Installation manual 00014869015 Safety Instructions Use only the specified power cables Iii System ConfigurationName Type Code No Qty Remarks Standard supplyName Type Code No Remarks Optional equipmentThis page is intentionally left blank Mounting considerations Antenna UnitSiting MountingMounting precaution for S-band antenna unit Installation precaution for S-band antenna unitAssembling the antenna unit Be sure to remove the guide pins after fixing the radiatorAttachment of lifting fixtures, collar and ropes How to hoist the antenna unitFastening the antenna unit to the mounting platform Installation of reinforcement ribsMounting the antenna unit Mounting procedure Monitor UnitFlush mounting Desktop mounting Contents of desktop mounting kit FP03-09820Attaching hand grips Fixing with KB keyboard fixing plate Control UnitMounting dimensions for control unit RCU-014 Mounting dimensions for control unit RCU-015/RCU-016Fixing without KB fixing plate Name Type Qty Contents of flush mount kit for RCU-014/015/016Control unit RCU-014, inside view Connecting RCU-016 in series with RCU-014Changing cable entrance on control unit RCU-015/RCU-016 Changing the cable entrance on control unit RCU-015/RCU-016Processor Unit Mounting dimensions for processor unitMounting dimensions for power supply unit Power Supply UnitWiring Overview WiringFabricating signal cable RW-9600 and HV cable TYPCY-1.5 Fabricating signal cable RW-9600Antenna unit, front view Armor Gasket Signal cable Flat washer Flat washer Gland nut How to fabricate HV cable TYPCY-1.5 How to wire Wago connectorHow to fabricate power cable TYPCY-2.5 Fabricating the power cable TYPCY-2.5Antenna unit, left-side view Passing flat washer, etc. onto HV cableFabricating power cable DPYC-2.5 Fabricating the power cable DPYC-2.5Monitor Unit for FAR-2167DS Monitor unit MU-201CR, rear viewProcessor Unit Connection of cables Processor unit, rear viewCable XH10P-W-6P L=20/30M Location of connectors inside the processor unit Location of connectorsPower cable TPYC-1.5 Signal cable RW-9600 Between antenna unit and processor unitPort Conventional remote display FAR-2167DS Connection of Sub-displayPower supply unit, inside view Fabricating cable connected to terminal TB1, TB2, TB3Terminal TB1 cable DPYC-2.5 Armor Power supply Fuse Jumper connector P108 Changing AC Power SpecificationProcessor unit Processor unit, inside viewHow to adjust the overvoltage detection circuit Power Fuse Jumper connector P8 Power supply unitHow to adjust the overvoltage detection circuit Initializing Tuning AdjustmentsHeading alignment Heading AlignmentFor Control Unit RCU-015 For Control Unit RCU-014Initialize menu Echo ADJ menuHow to access the Initialize Menu with Control Unit RCU-015 Examples of correct and incorrect sweep timings Adjusting Sweep TimingSuppressing Main Bang Echo menu setting Other SettingsScanner menu Blind Sector 1 and Blind SectorANT SW and ANT Stopped Installation menu Radar no and Radar PosnOn Time and TX Time OWN Ship Info menu LENGTH/WIDTH, Scanner Posn and SUB Scanner PosnGPS 1 ANT Posn and GPS 2 ANT Posn Arpa Preset menu ARP W/O Gyro Not shown on IMO radarARP-related menus ANT Select Other menu EAV w/o GyroOther menu This page intentionally left blank Gyro Converter GC-10 Installing the Gyro Converter boardFixing Gyro Converter board inside the processor unit Wiring Wago connector Connecting connector assemblies inside processor unitAttaching plastic cover for Gyro Converter board DIP switch, jumper wire settings Connection of external power supplyDefault setting Connection of external power supply to Gyro Converter boardJP1 JP1 JP2 JP3 JP4 JP5 Setting method 2 by make and model of gyrocompassGyro Converter board 64P1106HDG menu Setting the heading readout on the radar displayMemory Card Interface Unit Flush mounting dimensions for memory card interface unitDesktop mount ConnectionsOne memory card if unit and one processor unit One memory card if unit and multiple processor unitsType Code No Contents DVI-RGB Conversion Kit How to wire the DVI-RBG conversion boardProcessor unit bottom chassis Processor unit, side viewConnecting wires to the housing DVI-RGB BNC Connector ConverterData Specifications Contents Remarks InputOutput IEC 61162 output sentence IEC 61162 input sentence and prioritySentence and order of priority Sentence70+6 1 Packing List 76.+0 +26+10%1& 52 427 52 257 #%8 . . .   GC-10 $40# 14/Feb/2011 Y.NISHIYAMA Page May 1707 R.Esumi Sep/2010 Y.NISHIYAMA Page Jan.1808 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Page Page Page Page Page Page Page Page Page Interconnection Diagram