3.Select
4.Press the [ACQ/ENTER] key to display the ARP menu.
[ ARP MENU ]
Select item by omnipad and press ENTER key.
1. Display | Off | On | ||||
2 | . All Cancel |
|
|
|
|
|
3 | . Vector Ref | Rel | True | |||
4 | . Vector Length |
|
|
| 30S IM | |
5 | . History | 3M 6M 15M | 30M | |||
Off | 15S 30S | 1M | ||||
6 | . CPA Set | 2M | 3M 6M | |||
Off | 0.5 1nm 2nm | |||||
7 | . TCPA Set | 3nm | 5 nm 6nm | |||
| 30S | 1M 2M 3M | ||||
8 | . Auto ACQ |
| 4M | 5M 6M 12M | ||
Off | On |
Figure 6-1 ARP Menu
5.Select the menu item “1. Display.”
6.Select “On.”
7.Press the [ACQ/ENTER] key.
8.Press the [MENU] key to close the menu.
Deactivating the auto plotter
To deactivate the Auto Plotter;
1.Open the
2.Select the “1. Display.”
5.Select “Off.”
6.Press the [ACQ/ENTER] key.
7.Press the [MENU] key to close the menu.
Target Full Mark
Lost Target
Target under auto tracking but not selected for cursor data reading
HDG 234.5° | TRAIL AUTO | |
8 NM | 25:38 | 30M |
| G (OUT) | |
2 AUTO TARGET |
| ZOOM |
SP FULL |
| ES1 |
HU |
|
|
A/C |
|
|
|
|
AUTO |
|
|
| VRM |
EBL |
|
|
| |
345.6° R | 13.5° R | 0.142NM | 0.048NM | |
23.0° R |
|
| 0.100NM | |
| BEARING 42.5°T | COURSE 287.8°T | ||
TRUE VECTOR | RANGE | 5.36 NM | SPEED | 12.5 KT |
15 MIN | CPA | 2 NM | TCPA | 12:35 |
Target selected for data reading
Auto
Acquisition
Area
Threatening target
Auto Plotter
Data Area