Furuno 1712 installation manual Adjustments for Technicians

Page 19

3.4Adjustments for Technicians

1) Magnetron heater voltage

Magnetron heater voltage is formed at the MD Board of the antenna unit and preadjusted at the factory for use with any length of signal cable. Therefore no adjustment is required. However, verify heater voltage as follows:

CAUTION

Lift the radome cover slowly.

The antenna radiator may be caught by the screw holes in the radome cover.

If you feel the radiator is caught by the screw holes, lower the cover, turn it a few degree and then lift it again.

Screw holes (4 places)

Note: Turn the power on when measuring magnetron heater voltage.

1.Dismount the shield plate.

MD board under the shield plate

Figure 27 MD board

2.Turn on the power. Do not transmit the radar.

3.Connect a multimeter, set to 10 V DC range, between #6(+) and #4(-) of test point TP804 on the MD Board in the antenna unit.

4.Confirm that the multimeter shows 8.0 V ±0.1 V. If it does not, adjust potentiometer VR801 on the MD Board.

VR851

VR801

TP804

Figure 28 Antenna unit, inside view

13

Image 19
Contents Marine Radar Model MAY Safety Instructions Equipment Lists Installation MaterialsStandard Supply Optional Equipment Spare partsDisplay Unit System ConfigurationAntenna Unit Installation InstallationMounting considerations Mounting on a platform ScrewM4X15 Mounting using the optional mounting bracket Mounting Display Unit InstallationMounting dimensions of display unit Connections WiringConnection of external equipment Sounder Nmea connectionFixing MJ-XH connector assembly Adjustment of picture AdjustmentsInstallation Check AdjustmentsTotal hours radar Has been on Has been trans Menu Mitted Heading alignmentUnit of range measurement for VRM and cursor Sweep timingAdjustments for Technicians I/O Data Confirmation Restoring Default SettingsRadar function Page Page Oct ,02 Page Page