PROBLEM | REASON | SOLUTION |
|
|
|
Inverter does not | Poor contact at | Check for poor |
turn on. | terminals | connection to battery |
|
| or power supply. |
|
| Make sure connection |
|
| points are clean. Rock |
|
| clamps back and forth |
|
| for a better connection. |
| Fuse is blown. | A blown fuse is |
|
| usually caused by |
|
| reverse polarity or |
|
| a short circuit within |
|
| the inverter. |
|
| To replace, contact |
|
| a qualified service |
|
| technician who will |
|
| diagnose the inverter |
|
| and replace the fuse(s) |
|
| with the appropriate |
|
| replacement(s). |
| Inverter may be | See warranty and call |
| defective. | Customer Service |
|
| |
|
| (Hours 7:00 am to |
|
| 5:00 pm CST). |
9. SPECIFICATIONS |
|
|
|
Model: XI41DU |
| 410 Watts | |
Maximum Continuous Output. | ......................................... | ||
Surge Capacity (0.1 second) | 820 Watts | ||
Optimum Efficiency | 85% | ||
No Load Current Draw | <0.5A | ||
Output Frequency | 60Hz ± 3Hz | ||
Output Wave Form | Modified Sine Wave | ||
Input Voltage Range | 10.5V – 15.5V | DC | |
Low Battery Alarm | Audible, 11V | ± 0.3V | DC |
Low Voltage Shutdown | Under 10.5V | ± 0.3V | DC |
High Voltage Shutdown | Over 15.5V | ± 0.5V | DC |
• 10 •