Elinchrom Ranger RX manual Technical Data, Troubleshooting

Page 13

Technical Data

Ranger RX

Flashhead Ranger/Free Lite

Maximum power

J/Ws

Power range

J/Ws

Control range

f-stop

F-stop, 1m, 100 ISO, with reflector 48°

Recycling time fast @ Min/Max

s

power

 

Recycling time slow @ Min/Max

s

power

 

Flash duration @ t 0,5; 1 A and

s

2 A heads

 

Flashes, out of one charged Battery @ Min/Max Power, slow/fast, recycling

Modelling light output 12V

W

Power Pack 1100 17 - 1100 1,5 - 7,5

-

0,5 - 5,5

0,9 - 14

-

3800-2600

140-110

2x 50

Type S

2400

-

-

64

-

-

1/1150

1/2250

-

50/100*

Type A

2400

-

-

64

-

-

1/2300

1/4310

-

Ringflash 1500

1500

-

-

32,5

-

-

1/675

1/1680

-

-

*optional 100W halogen lamp, but only one head can be used. (code 23046)

Voltage across sync cable

-

Stabilisation

V

Battery lead acid

V/Ah

Battery recharge time, approx.

h

Dimension

cm

Weight

kg

5

+/- 1%

12V / 7Ah

3

19 x 14 x 24

6,5

-

-

-

-

22x 13,5

2,4

-

-

-

-

22x 13,5

2,4

-

-

-

-

22 x 13,5

2

Tolerances and specifications conforming to IEC and CE standards. Technical data subject to change without notice.

Troubleshooting

 

=> overheating

• Switch off the unit and let it cool down for at least 10mn

E.R.

 

=> Discharged Battery

• Needs recharging

 

 

• Battery charging fuse is brocken, replace fuses (page 10)

 

 

• Charger is brocken

 

 

• Battery is out of lifetime

 

=> Internal defect

• Do NOT open the unit yourself!

- -

 

 

• Bring your Ranger RX (with charger, heads, battery & cables)

 

 

to an Elinchrom service.

12

Image 13
Contents Ranger RX Battery Power PackTable of contents Ranger RX IntroductionFCC Class B Compliance Statement Disposal and recycling Declaration of conformityCE marking Notational ConventionsTravelling by Air as well as any other transport option User Safety InformationOutdoors Flash Tubes and Modelling lampsBefore you start BatteryPower Control Panel Overview of Controls SetupTest Charge/SyncAuto OFF Function Functions On/Off SwitchSlow Charge Photocell On/OffDigital Power Display Digital Power Regulation 7Battery Status Indicator Charge Ready BeepCharge Socket and Remote control Wireless Remote Control and Flash TriggeringHow to change the Battery Box Synchronisation SocketReplacement of fuses for Ranger RX Battery Charging / FusesRanger RX Sockets 16 Ranger/Free Lite S and a Flashheads Safety PrecautionsTroubleshooting Technical DataAccessories for Ranger RX only Elinchrom AccessoriesElinca sa Guarantee