Belkin F5C412uk140W, F5C412uk300W Installation, Power Source Requirements, Making the Connection

Page 5

Installation:

Power Source Requirements

The power source must provides 12 Volts DC and must be able to supply the necessary current to operate the load. The power source may be a battery or a well-regulated 12V DC power supply. As a rough guideline, divide the power consumption of the load (in watt) by 12 (the input voltage) to obtain the current (in amperes) the power source must deliver. Example: Load is rated at 120 Watts; the power source must be able to deliver: (220/12) = 18.3 Amps

Making the Connection:

The Belkin 140 and 300-Watt Inverters are designed to connect to your 12-volt battery through the cigarette lighter socket on your dashboard. To connect and use these Inverters, follow these easy steps:

1.Remove the cigarette lighter and push the adapter plug firmly into the socket. Make sure both the socket and adapter plug are clean and dry.

2.Plug your appliance or equipment into the AC receptacle on the Inverter.

3.Turn the Inverter rocker switch to the ON (l) position.

4.Confirm that the LED Power Indicator light on the Inverter is glowing GREEN. This GREEN light indicates that your Inverter is “ready for action.”

5.Turn on your equipment for use.

Don’t Blow a Fuse:

All Belkin Inverters are equipped with a spare fuse in case the original fuse should blow. Most blown fuses are the result of reverse polarity or a short circuit within the appliance or equipment being operated. With reasonable care, it should not be necessary to replace the fuse in your Inverter.

To Replace a Fuse:

Belkin 140-Watt / 300-Watt Inverter

First, remove the power cord from the cigarette lighter socket. You will find fuse compartment is easily accessed at the back of the unit underneath the “lift-up” cover. Pull the blown fuse out, and insert the replacement. It is important to remember that to replace of fuse of the same type and rating as indicated. Make certain to correct the source of the overload that caused the blown fuse before turning your Inverter back ON.

1. Open the fuse box cover

2. Replace the

 

blown fuse with

 

a new spade

 

type fuse

Image 5
Contents Class II product AC AnywhereImportant Information AC Anywhere Instructions and InformationGetting Off to a Good Start Don’t Push ItSolution TroubleshootingProblem F5C412uk140W SpecificationsPower Source Requirements InstallationMaking the Connection Don’t Blow a FuseBattery Level Indicator Power SourceAutomatic Shut-down and Related Safety Features Additional Safety Features Battery Direct-Connect CablesFor USE with Cigarette Lighter Plug Applicable only for the F5C412uk300wConnection to 12V Battery Using Battery Clips On/Off Battery LevelSwitch Indicator Lights