Belkin F5C412uk140W, F5C412uk300W Battery Direct-Connect Cables, Additional Safety Features

Page 7

Additional Safety Features:

1.Automatic shutdown when the internal circuit temperature exceeds standard design parameters for safe operation.

2.Continuous audible alarm:

a. When the input power from the 12-volt power source drops to 11 volts.

b. When the internal circuit temperature exceeds standard design parameters for safe operation.

In the event of automatic shut-down or continuous alarm, turn the Inverter rocker switch to the OFF (O) position until the source of the related problem has been identified and resolved.

Note:

The Belkin 300W model is equipped with a cooling fan that is only designed to run continuously while the Inverter is operating. Automatic shutdown caused by excess circuit temperature occurs when the cooling fan is unable to maintain the design parameters for safe operation of the Inverter.

To maintain your Inverter in proper working condition, note the following important safety precautions:

MOISTURE - Keep the Inverter dry. Do not expose it to moisture.

HEAT – The ambient air temperature should be between 50ºF and 80ºF, (approx. 17ºC - 27ºC). Avoid placing the Inverter on or near heat source. Do not place the Inverter in direct sunlight.

VENTILATION – In order to disperse the heat generated while the Inverter is in operation, keep it well ventilated. While in use, maintain several inches of clearance around the top and sides of the Inverter.

Caution: Most automobole cigarette lighter circuits use fuses rated at 10-20 Amps.

Battery Direct-Connect Cables:

For the Belkin 300-Watt Inverter Only – F5C412uk300W

Note:

If the equipment or appliance you intend to operate requires more than 150 Watts of continuous power, the Belkin 300-Watt Inverter should be connected directly to the power source using the Battery Direct-Connect Cables. Failure to do so may result in serious damage to the power cord or to the cigarette lighter socket wiring in your vehicle.

Image 7
Contents Class II product AC AnywhereDon’t Push It AC Anywhere Instructions and InformationImportant Information Getting Off to a Good StartProblem TroubleshootingSolution F5C412uk140W SpecificationsDon’t Blow a Fuse InstallationPower Source Requirements Making the ConnectionAutomatic Shut-down and Related Safety Features Power SourceBattery Level Indicator Additional Safety Features Battery Direct-Connect CablesFor USE with Cigarette Lighter Plug Applicable only for the F5C412uk300wConnection to 12V Battery Using Battery Clips On/Off Battery LevelSwitch Indicator Lights