Xantrex Technology 813-1000-UL manual Problem Possible Cause Solution

Page 29

 

 

Troubleshooting

Table 1 Troubleshooting Reference

 

 

 

 

 

 

 

Problem

Possible Cause

Solution

 

 

 

 

 

Low output voltage (96 VAC–104 VAC)

You are using a voltmeter that cannot

Use a true RMS reading voltmeter such as the

 

 

accurately read the RMS voltage of a

Fluke 87.

 

 

modified sine wave.

 

 

 

Low input voltage and the load is close to

Check the connections and cable to see if the

 

 

maximum allowable power.

battery is fully charged. Recharge the battery

 

 

 

if it is low.

 

 

 

Reduce the load.

 

 

 

 

 

No output voltage. Both the Power Light and

The inverter is off.

Turn the inverter on.

 

Fault Light are off.

 

 

 

 

No power to the inverter.

Check the wiring to the inverter and to the

 

 

 

battery selector switch (if installed).

 

 

The inverter could have been connected with

The inverter has probably been damaged.

 

 

reverse DC input polarity.

Return the unit. Damage caused by reverse

 

 

 

polarity is not covered by the warranty.

 

 

 

Information for returning the inverter is

 

 

 

provided in “Return Procedure” on page 23.

 

 

 

 

 

No output voltage. Power Light is on.

GFCI was tripped.

Reset GFCI.

 

 

 

 

 

975-0557-01-01

17

Image 29
Contents XPower 1000 Inverter Page Date and Revision Purpose About This GuideRelated Information Reference Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Regulatory Precautions When Placing the InverterPage Contents Page Introduction Quality PowerEase of Use Comprehensive ProtectionMaterials List Inverter Materials ListAC Panel Inverter FeaturesDescription DC PanelPrepare for Installation Inverter InstallationInstallation Code Charging System Typical Power System DesignBattery Requirements Fuses or Circuit Breakers LocationCables for DC Input and Ground Overview of Installation Steps Install the InverterConnect the Chassis Ground Mount the InverterDamage from a Reverse Polarity Connection Connect the DC CablesInverter Installation Turning the Inverter on and OFF Inverter OperationOperating Limits Testing the GfciOperating Several Loads at Once Inverter Loads Connecting Appliances to the InverterRoutine Maintenance Recharging batteries Testing the GfciCommon Problems TroubleshootingBuzz in Audio Equipment Television ReceptionTroubleshooting Reference Problem Possible Cause Solution Troubleshooting Electrical Specifications SpecificationsWarranty Warranty and Return InformationWarranty and Return Information Product DisclaimerReturn Procedure Return Material Authorization PolicyInformation About Your System Page Xantrex Technology Inc