Tyan Computer B5382 manual Removing the Front Door Assembly

Page 55

3.4Removing the Front Door Assembly

A door is supplied with the FT48-B5382 that can be used when the unit is rack mounted or standalone. Follow these instructions to remove the door.

1.Pull out the four fixing bars locking the door assembly onto the server.

2.Remove the door assembly from the four holes located on the lower edge of the server.

To replace the door assembly:

1.Tilt the door assembly and fit the four protruding tips into the holes located on the lower edge of the server.

2.Place the door assembly in place and make sure that the four fixing bars are locked onto the server.

Chapter 3: Replacing Pre-installed Components

47

Image 55
Contents Tank FT48 B5382 Service Engineer’s Manual Page Disclaimer CopyrightTrademark Recognition Federal Communications Commission About this Manual Safety Information Table of Contents Technical Support About the Tyan Tank FT48-B5382 OverviewProduct Model Model Supported HDD Hot Power supply Type & quantityEnclosure FeaturesBios Unpacking Box Contents Component DescriptionComponent Description Accessories Sliding Rail Kit Option System Front View and Front Panel About the ProductSystem Rear View B5382F48W8H B5382F48W8HR Color State Description System Top View for FAN LEDsColor Description LED Control PanelRear LEDs HDD Tray LEDsMotherboard Layout JP7/JP8 Jumpers & Connectors Jumper/Connector Function9 B5382 System Block Diagram System Internal View Overview Work Area Before You BeginTools Precautions Removing the Chassis Cover Installing Motherboard ComponentsInstalling the CPUs and Heatsinks Setting Up Setting Up Installing the Memory Setting Up Setting Up M5382 Layout PCI-X slots PCI-E x16 slots PCI slot Installing the PCI/PCI-X/PCI-E CardsSetting Up Installing Hard Drives Setting Up Setting Up Installing the Second DVD-ROM Option Setting Up Installing the Floppy Disk Drive Option Setting Up Setting Up Setting Up Installing Chassis Foot Stands Opening the Chassis Door Installing the Security Tab Introduction Replacing Pre-installed ComponentsPrecautions Following flowchart outlines the disassembly procedure Disassembly FlowchartRemoving the Chassis Cover Removing the Front Door Assembly Replacing Motherboard Components Disconnecting All Motherboard CablesReplacing the Motherboard Replacing the Cooling Fans Replacing the Fan Control Board Replacing Pre-installed Components Fan Board Features Fan Board Connector Pin Definition Replacing the SAS/SATA Backplane Rear View 1 M1211 SAS/SATA Backplane Features2 M1211 SAS/SATA Backplane Connector Pin Definition Replacing the LED Control Board Replacing Pre-installed Components 1 M1007 LED Control Board Features 2 M1007 LED Control Board Connector Pin Definition Replacing the DVD-ROM Replacing Pre-installed Components Standard Power Supply Replacing the Power SupplyRedundant Power Supply Replacing Pre-installed Components B5382 Advanced/Hardware Health Information Appendix I Bios DifferencesPeci S5382 Advanced/Hardware Monitor InformationSAS/SATA Cables Power Supply CablesFAN Cables Power Supply to FAN Board LED Control Board to Motherboard Other CablesAppendix III Installing the Smdc Card Option Page Cable Connection Table Appendix IV Rack Mounting Option Installing the 5.25 Devices in Rackmount PositionPage Page Sliding rail kit Option Installing the Server in a RackScrews List Installing the Inner Rails to the Unit Installing the Outer Rails to the Rack Page Rackmounting the Server Page Help Resources Technical SupportReturning Merchandise for Service