4. REMOVAL AND REPLACEMENT OF COMPONENTS

[a]ELECTROLYTIC CELL

WARNING

To prevent electric shock, be careful not to crush or drag the pipes or wires when removing the electrolytic cell.

NOTICE

To prevent water leaks resulting in wetting the surrounding properties, be sure to drain water before removing the electrolytic cell.

1)Remove the front panel, turn off the power switch (ground fault interrupter), and unplug the unit.

2)Close the water supply line shut-off valve, and disconnect the water supply, cleaning water, and sanitizing water hoses.

3)Unscrew and remove the top and side panels.

4)Remove the drain cap on the back of the unit to drain the electrolytic cell.

5)Disconnect the power cord (red/black) on the electrolytic cell from the terminal block.

6)Remove the four union nuts from the electrolytic cell.

7)Unscrew the cell stopper and frame assembly, and remove the cell stopper from the unit base.

8)Slide out the electrolytic cell towards you.

9)To replace, reverse the above pocedure.

30

Image 31
Contents ROX-20TB2-U Hoshizaki AMERICA, INC Contents Unit Serious injuryProperty Indicates important information about the use and carePage General Information Safety Instructions Page Product Information Model Name ROX 20 T B2 UDIMENSIONS/SPECIFICATIONS Performance Data II. Technical Information Principle of Electrolysis H2O Page General ConstructionPage Mechanism Control BOX Page Wiring Diagram Water Circuit Functions and Operation Normal ModeShort Mode Adjustment ModeCheck Mode C10 Elapsed time after regeneration output h Display On on Body Display Service Diagnosis III. Service Information Error CodesEE1 Flow Rate Adjustment Electrolytic Cell Removal and Replacement of Components