Hoshizaki ROX-20TB2-U service manual III. Service Information Error Codes, Service Diagnosis

Page 28

III.SERVICE INFORMATION

1. ERROR CODES

Lamp

No.

Error

Problem

Operation

Control panel

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow rate stayed below 0.13

Production stops after

 

Error

E11

Low water

gal/min (0.5 L/min) for 10 sec

water valve turns off

Error no.

 

 

 

with water valve on

two times

 

 

 

 

Flow rate stayed above 0.13

Production stops after

 

Error

E14

Water shutoff

gal/min (0.5 L/min) for 10 sec

water valve turns on

Error no.

 

 

 

with water valve off

two times

 

Error

E53

Contactor supply

Current stayed below 0.5A for 2

Production stops after

Error no.

sec

contactor switches

 

 

 

 

three times

 

Error

E61

Flow switching

Switching did not complete

Production stops

Error no.

valve

within 30 sec

 

 

 

 

 

 

 

 

 

Open circuit [-22°F (-30°C)] or

Production continues

Alternate between

E74

Thermistor

as 41°F (5°C) (open

normal display

short circuit [140°F (60°C)]

circuit) or 86°F (30°C)

 

 

 

and error no.

 

 

 

 

(short circuit)

 

 

 

Float switch (if

Upper switch on, lower switch

Production continues

Alternate between

E82

provided with

normal display

 

 

tank)

off

(for at least 3 min)

and error no.

 

 

 

 

Add salt

 

 

Salt water pump stayed at 700

 

 

Salt water level

spm (strokes per minute) for 90

Production stops

(Add salt lamp on)

water

 

 

sec

 

 

 

 

 

 

 

EE1

Model setting

Model setting connector lost or

Production stops

Error no.

 

 

 

wrong

 

 

Error

EF0

Control board

EEPROM error

Production stops

Error no.

2. SERVICE DIAGNOSIS

Lamp

Error code

Problem

Check

Possible cause

Remedy

Add salt

Salt water pump stayed

Salt water tank

Low salt water

Add salt in salt

water

 

700 spm (strokes per

 

concentration

water tank

 

 

minute) for 90 sec

Salt water hose

Loose connection to

Reconnect

 

 

 

 

salt water tank

 

 

 

 

 

Clogged

Unclog

 

 

 

 

Vapor lock

Prime

 

 

 

Filter

Dirty

Clean

 

 

 

Switching

Defective

Repair or replace

 

 

 

regulator

DC supply line open

Correct

 

 

 

(electrolytic cell)

circuit

 

 

 

 

Magnetic switch

Defective

Repair or replace

 

 

 

 

Bad contacts

Repair

 

 

 

Relay

Defective

Repair or replace

 

 

 

 

Bad contacts

Repair

 

 

 

Current sensor

Defective

Repair or replace

27

Image 28
Contents ROX-20TB2-U Hoshizaki AMERICA, INC Contents Serious injury PropertyIndicates important information about the use and care UnitPage General Information Safety Instructions Page Product Information ROX 20 T B2 U Model NameDIMENSIONS/SPECIFICATIONS Performance Data II. Technical Information Principle of Electrolysis H2O Page Construction GeneralPage Mechanism Control BOX Page Wiring Diagram Water Circuit Normal Mode Short ModeAdjustment Mode Functions and OperationCheck Mode C10 Elapsed time after regeneration output h Display On on Body Display III. Service Information Error Codes Service DiagnosisEE1 Flow Rate Adjustment Removal and Replacement of Components Electrolytic Cell