Setup
Setup
Follow the instructions below to setup dosing valve 255478 on a XM
NOTE:
Dosing valve 245846 was used on the old Xtreme Mix™ and should not be installed on XM sprayers.
1.Remove plug (31) if 255478 will be used on a machine with pressure transducers (P).
NOTE:
Valves are shipped with the parts orientated as a hard- ener valve.
2.Resin dosing valve (left side): Remove screws (27) and turn seat housing (26) 90° so that the side ports are facing to the left for the sampling valve (S) and to the rear for the temperature sensor (not shown). See FIG. 1.
3.Hardener dosing valve (right side): If necessary, remove screws (27) turn seat housing (26) 90° so
that the side ports are facing to the right and rear for the sampling valve (S) and temperature sensor (T).
4.Transfer all valves, fittings, and sensors from the dosing valve being removed from the machine to the new valve.
5.Use new
6.If not using sampling valve (S), plug port with plug (29).
7.Replace seat housing (26) with screws (27).
8.Fill dosing valves A and B packing nuts (7) with throat seal liquid (TSL) and tighten 1/4 turn after nut contacts packings; about
9.See XM
Resin (Left) | Hardener (Right) |
7
|
|
| 7 |
16 |
|
| 16 |
|
|
| |
P |
|
| 8 |
|
|
| |
|
|
| R |
|
| 8 |
|
R |
| P |
|
S |
|
| S |
26 | 27 | 27 26 | r_313259_313342_2 |
|
|
|
FIG. 1: Hardener and Resin Dosing Valve 255478 Orientation
313342D | 5 |