Parts
Parts
255478, Dosing Valve for XM Plural-Component Sprayers
1
2
11
12
73
13 15
14
4
23
5
1
1.Apply pipe sealant to
30
8 19
46
8 10
31 32
1136
12 33
24 10
26
7 6
17 8
18
6 4
3
9
8
16 4
25 9
29 12
2.Apply lubricant to threads,
3 | Apply blue thread lock. Thread to bottom. |
4 | Torque to |
5 | Torque to |
6 | Tighten packing nut 1/4 turn after nut bottoms out; |
| |
| about once a month. Keep packing nut filled with TSL. |
7 | Lubricate and press piston evenly into cylinder. |
8 | Clean ball housing (10) and packing cavity before |
| reinstalling packings (17, 18, 19). Lubricate packings and |
| install with lips facing down away from packing nut (7) in |
| order shown. |
27 5
r_313259_313342_3
9Replace
10Inspect reversible seat for damage. If one side is worn, reverse seat.
11Use
12Use if recirculation valve is not used.
8 | 313342D |