Graco 309868D important safety instructions Equipment Misuse Hazard, Pressurized Equipment Hazard

Page 2

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING

Equipment Misuse Hazard

Misuse can cause death or serious injury.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your Graco distributor for information.

For professional use only.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not use hoses to pull equipment.

Comply with all applicable safety regulations.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

SKIN INJECTION HAZARD

High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

Do not point gun at anyone or at any part of the body.

Do not put your hand over the spray tip.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Do not spray without tip guard and trigger guard installed.

Engage trigger lock when not spraying.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

2

309868D

Image 2
Contents Contents Mini Fire-Ball225 Oil PumpEquipment Misuse Hazard Pressurized Equipment HazardMoving Parts Hazard Installation Mounting the Pump GroundingOperation Pressure Relief ProcedureStarting and Adjusting the Pump Troubleshooting Problem Cause SolutionBefore You Start Air Motor and Throat ServiceDisassembly Clean and Service ReassemblyCutaway View Air Motor and Throat Service Displacement Pump Service Flush the pump and relieve the pressureDisplacement Pump Service 309868D Parts No. Part No. Description Qty Part No. Description QtyTechnical Data Data measured with 10 weight oil at 70F 21COrder gasket 15R881 for sealed tank/drum mounting Dimensional DrawingsMounting Hole Layout Graco Standard Warranty Graco Information