Parker Hannifin HD130, HD65 manual Fault-finding Guide

Page 27

HD65 & HD130 STEPPER DRIVES USER GUIDE 19

Fault-finding Guide

If there is no response from the motor and the more obvious checks have been made, the following guide may help to identify the problem. Before going through the procedure, make sure that the motor shaft is free to rotate with the drive switched off.

Turn the drive on and see which LEDs are illuminated. Then go to the appropriate heading below.

Zero phase -

listen for audible noise from the motor. If there

 

is none, check for open-circuit motor leads,

 

check energise input (motherboard switch 9 on

 

or terminal 7 connected to 0v).

Overload -

switch off, disconnect the motor and switch on

 

again. If the overload LED is still on, the drive

 

has been damaged. If not check for short

 

circuits or crossed motor connections. A very

 

low inductance motor could also cause the

 

drive to trip out, if this is suspected try

 

connecting the motor in series.

Supply failure -

check the AC supplies coming into the

 

motherboard. If these are OK, switch off, wait

 

for 3 minutes, unplug the drive and check the

 

fuses on the back of the motherboard. If OK,

 

there is probably an internal failure within the

 

drive.

Over-temperature - the drive has overheated and should be

 

switched off and left to cool. If it was previously

 

working satisfactorily, better cooling is needed.

 

On the HD130, check that the fan is running

 

and is not obstructed.

None at all -

check as for "supply failure".

If there is audible noise from the motor but the drive does not respond to clock pulses, look to see if the zero phase LED flashes. If clock pulses are entering the drive, the LED should flash or go dim depending on speed. If it doesn't, the drive is either not getting any pulses or is not responding to them. Make sure the clock pulses go low for at least 4uS and that the logic low level is below +1v.

CAUTION

Note that if the dump fuse (FS2) is blown it will take approxi- mately 3 minutes for the main supply capacitor to discharge. Always allow adequate time for the capacitor to discharge

Image 27
Contents HD65 & HD130 Stepper Drives User Guide Page Important Information for Users Page User Guide Change Summary Page Table of Contents Page Product Description SpecificationIntroduction HD65 & HD130 Stepper Drives User GuidePower Connections General Wiring Earthing Recommenda TionsHD65 & HD130 Stepper Drives User Guide Power and Motor Connections Connections PrimaryMotor Connection Data Windings in Series Motor Connection Data Windings in Parallel SK1 Control SignalsHD65 & HD130 Stepper Drives User Guide 10 HD65 & HD130 Stepper Drives User Guide Setting Up DriveDIP Switch Settings Motor Current For HD65 12 HD65 & HD130 Stepper Drives User Guide Normal Current Profile Half-step Mode 14 HD65 & HD130 Stepper Drives User Guide FusesTest Points Setting Up Microstep Card MS20 Microstep CardDescription Sinewave FILLED-OUT Trimmed 16 HD65 & HD130 Stepper Drives User GuideSupply Over- temperature ProtectionOperation of the Drive Protection Systems Overload ProtectionProtection Circuit 18 HD65 & HD130 Stepper Drives User GuideFault-finding Guide Returning the System 20 HD65 & HD130 Stepper Drives User GuideHD65 & HD130 Stepper Drives User Guide