Emerson 600 installation instructions R M, Installation Instructions, 9884E June

Page 1

Tenso-set™ Series 600

Auto-Tensioning Motor Base

Installation and Maintenance Manual

Emerson Industrial Automation

7120 New Buffington Road

Florence, KY 41042

Application Engineering: 800 626 2093 www.PowerTransmissionSolutions.com

F O R M

9884E

June 2014

WARNING

Read and follow all instructions carefully.

Disconnect and lock-out power before installation and maintenance. Working on or near energized equipment can result in severe injury or death.

Avoid contact with energized circuits or rotating parts.

Be sure shaft key is fully captive before unit is energized.

Do not operate equipment without guards in place. Exposed equipment can result in severe injury or death.

CAUTION

Periodic inspections should be performed. Failure to perform proper maintenance can result in premature product failure and personal injury.

All electrical work should be performed by qualified personnel and compliant with local and national electrical codes.

Carriage Rods

Motor Carriage

Tension Rod

Tension Nut

Installation Instructions

Mounting Brackets

1. Mount the motor on the motor base using the recommended

2. Mount the sheaves on the Driver and Driven Shafts.

grade 5 bolts and torques listed in table 1.

 

Table 1

Motor Base

Bolt Size

Torque (Grade 5 plated )

 

 

 

BSAMBN601

5/16-18

13 Lb-Ft

BSAMBN605

3/8-16

23 Lb-Ft

BSAMBN607

3/8-16

23 Lb-Ft

BSAMBN613

3/8-16

23 Lb-Ft

BSAMBN621

1/2-13

57 Lb-Ft

BSAMBN623

1/2-13

57 Lb-Ft

Browning, Emerson and Emerson Industrial Automation are trademarks of Emerson Electric Co. or one of its affiliated companies.

©2014 Emerson Power Transmission Corp., All Rights Reserved. MCIM14006E • Form 9884E • Printed in USA

1

Image 1
Contents R M Installation Instructions9884E June Check the belt tension using Browning Belt Tension Checker Adjusting Belts MaintenanceAllowable Mounting Positions Lubrication