Furuno FCV-582L Turning On/Off the Power, Adjusting Tone and Brilliance, Selecting a Display

Page 11

1.3 Turning On/Off the Power

Press the POWER key to turn the power on/ off. When the unit is turned on it proceeds in the sequence shown below.

ROM: OK

ROM and RAM

RAM: OK

check; displayed for

several seconds.

 

Note 1: Location of arrow keys on the bril- liance setting is opposite of same controls on the control panel.

Note 2: Tone or brilliance must be adjusted within about 10 seconds after pressing the BRILL key or the tone and brilliance display will be erased.

PROGRAM No: 02522790** ** Program version

no.

You may press any key to show the sounder display immediately.

 

200k

Sounder

0.0

0

 

 

display

 

20

 

 

40

 

 

60

 

49.6

80

 

Figure 1-3 Start-up sequence

Note: Wait at least five sec. before reapply- ing the power.

1.4 Adjusting Tone and Brilliance

1.Press the BRILL key. The tone and bril- liance setting display appears.

LOW– +HIGH

TONE : 5

LOW▼ ▲HIGH

BRILL : 7

Figure 1-4 Tone and brilliance

setting display

2.Press the [+] or [–] key to adjust display tone.

3.Press the [] or [] key to adjust dis- play brilliance.

1.5 Selecting a Display

Six basic displays are available: nav (data or graphic mode selectable on the system menu), low frequency, dual frequency, high fre- quency, zoom (marker zoom, bottom zoom, bottom lock), and menu. (An A-scope display is also available with the BRILL and ALARM keys.)

1.Operate the MODE control to select a dis- play mode.

2.For zoom mode, press the ZOOM key.

ZOOM MODE

BOTTOM LOCK BOTTOM ZOOM

MARKER ZOOM

Figure 1-5 Zoom mode selection display

Normal display

Low frequency (50 kHz) display

The sounder uses ultrasonic pulses to detect bottom conditions. The lower the frequency of the pulse, the wider the detection area. Therefore, the 50 kHz frequency is useful for general detection and judging bottom condi- tion.

50 kHz

200 kHz

Figure 1-6 Comparison of detection ranges

of 50 kHz and 200 kHz transducers

3

Image 11
Contents Color LCD Sounder First Edition APR Safety Instructions Table of Contents Iii FeaturesForeword Word to FCV-582L OwnersUser Menu Menu TreeDisplay Unit System ConfigurationPrinciple of Operation Control Description Operational Overview22.6 C 12kt NL1 200k Indications, MarkersNormal display Turning On/Off the PowerAdjusting Tone and Brilliance Selecting a DisplayDual-frequency display 49.628.2 Marker-zoom displayData display Bottom-zoom display36.4 Bottom-lock display69.4 m Graphic displayBasic range selection Adjusting the GainSelecting Display Range Selecting data or graphic displayHow it works How to enable automatic operationAutomatic Operation Selecting Picture Advance SpeedMeasuring Depth Erasing Weak EchoesUser Menu Scope Display32.3 Selecting Background and Echo Colors Suppressing InterferenceSuppressing Low Level Noise Alarms White Marker Fine Adjustment of Gain in Dual-Frequency OperationSystem Menu Optional ModeDisplaying the Optional Mode Menu System menu 3 description System menu 1 descriptionSystem menu 2 description Bottom Level Demonstration DisplayEcho Offset TVG LevelBottom Echo Interpreting the DisplayZero Line Fish School EchoesSurface noise/aeration Surface Noise/AerationChecking Maintenance & TroubleshootingCleaning the Display Unit Transducer MaintenanceTroubleshooting TroubleshootingTest Pattern TestClear memory display Clearing the MemorySpecifications of Color LCD Sounder Power Supply Index-1 IndexIndex-2