Furuno FCV-582L System menu 1 description, System menu 2 description, System menu 3 description

Page 23

System menu 1 description

MENU: Selects system menu desired.

DEPTH UNIT: Selects unit of depth mea- surement among meters, feet, fathoms, or passi/braza. Default setting is feet.

SPEED UNIT: Selects unit of speed measure- ment among knots, miles per hour, or kilo- meters per hour. Default setting is knots. Requires speed data.

TEMP UNIT: Selects unit of temperature measurement; Celsius or Fahrenheit. Default setting is Fahrenheit. Requires temperature data.

ZOOM MARK: The zoom marker appears in the normal, bottom marker and bottom zoom displays and marks the area which is expanded in the bottom marker and bottom zoom pictures. You can turn on/off the marker as desired. The default setting is off.

F/A (Fish Alarm) LEVEL: Selects minimum echo strength level which triggers fish alarm; weak, medium, or strong. Default setting is medium.

TEMP GRAPH: Displays current water tem- perature in line graph form. (See illustration on page 2.) Default setting is off. Requires water temperature data.

LANG: Selects menu language; Japanese, English or etc. Default setting is English.

DISP SEL: Selects navigation displays: GRA1, steering display; GRA2, speed meter display; DATA, date display. Default setting is GRA1.

DRAFT: The zero line (sometimes referred to as the transmission line) represents the transducer’s position, and moves off the screen when a deep phased range is used.

TX OUTPUT: Selects transmitter output level; maximum or minimum.

System menu 2 description

MENU: Selects system menu desired.

NAV DSP: Selects nav data to display on the video sounder displays; position (L/L), range and bearing (R/B), or course (CSE). (For the location of the nav data indication, see the il- lustration on page 2.) Default setting is off. Requires nav data input.

NMEA: Selects NMEA data input format; Ver. 1.5 or Ver. 2.0. Default setting is Ver. 2.0.

BEARING: Ship’s course and bearing to a waypoint may be displayed in true or mag- netic bearing, on the graphic display. Mag- netic bearing is true bearing plus (or minus) earth’s magnetic deviation. Default setting is magnetic. Requires bearing data.

SPD SEL: Selects source of speed input; OFF, OWN (speed sensor), or NMEA (external). Default setting is OWN. Requires speed data.

TMP SEL: Selects source of water tempera- ture input; OFF, OWN (water temperature sensor), or NMEA (external). Default setting is OWN. Requires water temperature data.

SPD ADJ: If the speed sensor-generated speed indication is wrong, you can correct it here. (NMEA format speed data cannot be ad- justed.) For example, if the speed indication is 10% higher than actual speed, enter +10. Default setting is zero.

TEMP ADJ: If the water temperature sen- sor-generated water temperature indication is wrong, you can correct it here. (NMEA for- mat water temperature data cannot be ad- justed.) For example, if the water temperature indication is 2° higher than actual water tem- perature, enter -2. Default setting is zero.

System menu 3 description

MENU: Selects system menu desired.

BASIC RANGE 1–BASIC RANGE 8: Set range of each of the eight basic ranges. De- fault basic ranges are 15, 30, 60, 120, 200, 400, 1000, and 2500 (feet).

16

Image 23
Contents Color LCD Sounder First Edition APR Safety Instructions Table of Contents Iii FeaturesForeword Word to FCV-582L OwnersUser Menu Menu TreeDisplay Unit System ConfigurationPrinciple of Operation Control Description Operational Overview22.6 C 12kt NL1 200k Indications, MarkersNormal display Turning On/Off the PowerAdjusting Tone and Brilliance Selecting a DisplayDual-frequency display 49.628.2 Marker-zoom displayData display Bottom-zoom display36.4 Bottom-lock display69.4 m Graphic displayBasic range selection Adjusting the GainSelecting Display Range Selecting data or graphic displayHow it works How to enable automatic operationAutomatic Operation Selecting Picture Advance SpeedMeasuring Depth Erasing Weak EchoesUser Menu Scope Display32.3 Selecting Background and Echo Colors Suppressing InterferenceSuppressing Low Level Noise Alarms White Marker Fine Adjustment of Gain in Dual-Frequency OperationSystem Menu Optional ModeDisplaying the Optional Mode Menu System menu 3 description System menu 1 descriptionSystem menu 2 description Bottom Level Demonstration DisplayEcho Offset TVG LevelBottom Echo Interpreting the DisplayZero Line Fish School EchoesSurface noise/aeration Surface Noise/AerationChecking Maintenance & TroubleshootingCleaning the Display Unit Transducer MaintenanceTroubleshooting TroubleshootingTest Pattern TestClear memory display Clearing the MemorySpecifications of Color LCD Sounder Power Supply Index-1 IndexIndex-2