Furuno GP-1850DF installation manual Safety Instructions for the Installer

Page 3

SAFETY INSTRUCTIONS

Safety Instructions for the Installer

WARNING

Do not work inside the equipment unless totally familiar with electrical circuits.

Hazardous voltage which can shock, burn or cause serious injury exists inside the equip- ment.

Turn off the power at the mains switchboard before beginning the installation. Post a sign near the switch to indicate it should not be turned on while the equip- ment is being installed.

Fire, electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed.

CAUTION

Ground the equipment to prevent electrical shock and mutual interference.

Confirm that the power supply voltage is compatible with the voltage rating of the equipment.

Connection to the wrong power supply can cause fire or equipment damage. The voltage rating appears on the label at the rear of the display unit.

Use the correct fuse.

Use of a wrong fuse can cause fire or equipment damage.

Keep the following compass safe distance.

Standard Steering

Display Unit

0.98 m

0.74 m

When handling the transducer cable, keep in mind the following points.

Keep the cable away from oil and fuel.

Keep the cable away from the place where it may be damaged during the installation.

Do not paint the cable.

The sheath of the transducer cable is made of chlorophrene rubber (or vinyl chloride). Therefore, do not paint the sheath with organic liquid (such as toluene) since it may harm the sheath.

i

Image 3 Contents
AP-1 Installation of Dgps Beacon ReceiverB . N o . I M E 4 3 9 5 0 J Safety Instructions for the Installer Safety InstructionsOptional equipment Standard supplyIii System Configuration Mounting considerations Installation of Display UnitMounting procedure Tabletop, overhead mountingFlush mounting Flush mounting of display unit Installation of Antenna UnitNecessary tools Installation of TransducersInstalling the inside-hull mount transducer Remarks on installationCoating the transducer face with silicone sealant Attaching the transducerMODE/FREQ Auto Cruising Auto Fishing Manual Observing the pictureFinal preparation Installing the thru-hull mount transducer Transducer mounting locationTransducer outline drawings Acceptable transducer mounting locations Typical through-hull mount transducer installations15 Construction of fairing block Procedure for installing the thru-hull mount transducer16 Transom mount transducer mounting locations Installing the transom mount transducer17 Transom mount transducer, mounting flush with hull Transducer preparationMounting considerations Triducer 524ST-MSD, 525ST-MSDTransom mount water temperature sensor Installation of Sensors21 Thru-hull mount water temperature sensors 02MSB, T-03MSB Thru-hull mount water temperature sensor 02MSB, T-03MSBST-02PSB Power cable WiringGround Water temperature/speed sensorAntenna unit TransducerCable extension Extending antenna cable lengthHow to attach the N-P-8DFB connector Nmea port Nmea SettingRTCM104OUTPUT Dgps portRTCM104EXTRN RTCM104INTRNInput/Output Sentences Output Data SentencesAntenna Height Baud Rate Setting GP-1850DF onlyBeacon Baud Rate Beacon Frequency Setting GP-1850DF onlyBeacon Frequency Auto Depth AdjustmentExternal Equipment Setup Option Speed SourceSpeed Source OWN Pddwhl GPS Speed Adjustment Temperature AdjustmentSpeed ADJ Temp Graph OFF Temp ADJ14 Display unit, top view Selecting the Echo Sounder Output Power15 Removing cover assembly 17 Inside of the cover Installation of Dgps Beacon Receiver for GP-1850F Procedure DisassemblyDismounting chassis assembly Installation of Dgps receiverInstallation of Dgps beacon receiver Wiring the Cable assembly Attaching chassis assembly 10 Inside of the cover Checking the Dgps installationAppendix Triducer 525ST-PWC/PWD AP-2 AP-3 Page Page Page Page 11 Connecting Dgps beacon receiver Connecting Dgps beacon receiverPage Page Page Page Page Page Page Page