Graco 307212ZAC important safety instructions Service of the Air Operated Regulators

Page 12

Service

Service of the Air Operated Regulators

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1.Shut off the pump.

2.Close the ball valve at the regulator’s air inlet. Refer to Fig. 2.

3.Release all the air and fluid pressure in the regula- tor and disconnect the air and fluid lines.

4.Remove the regulator from the system.

5.Remove the swivel union (23) and spring (40) from the regulator body.

6.Remove the ball (20), seat (16), and gasket (15). See Fig. 4.

CAUTION

Use special care when handling the hard carbide ball (20) and seat (16) to avoid damaging them.

NOTE: Gasket (15) is thin and translucent. Be sure to remove the gasket.

7.Remove the six cap screws (1) and housing (6).

8.Place diaphragm assembly in a vise, with jaws on stem housing (18). Remove the retaining screw (10), jam nut (13) and washer (17) from the stem housing (18).

9.Remove the diaphragm (22) and gasket (26).

10.Remove the spring (3), valve stem (9), and gasket

(21)from the stem housing (18).

11.Thoroughly clean and inspect all parts. Replace any parts that appear to be worn or damaged.

12.Place stem housing (18) in a vise. One at a time, place the gasket (26), diaphragm (22) – white PTFE side down toward the bottom housing, and washer (17) on the stem housing (18). Secure them with the jam nut (13). Torque the jam nut onto the stem housing to 21–35 ft-lb (28–47 NSm).

13.Install the valve stem (9), spring (3), gasket (21), and retaining screw (10) in the stem housing (18). Make sure the tab on the valve stem (9) fits into the slot on screw (10).

14.Torque the retaining screw into the housing to 21–25 ft-lb (28–34 NSm).

15.Install the assembled parts in the housing (6).

16.On Model 214980, tighten the air line fitting (29) into the cap (7). Torque to 21–35 ft-lb (28–47 NSm).

17.Install the cap (7). Tighten the six cap screws (1) in the sequence shown in Fig. 4, Bottom View, and to the torque noted.

18.Install the gasket (15), valve seat (16), and ball

(20)into the housing (6).

NOTE: Seat may be turned upside down and reused.

19.Screw the swivel union (23), with the o-ring (4) attached and the spring (40) in place, into the inlet. Torque to 23–27 ft-lb (31–36 NSm).

12 307212

Image 12
Contents Instructions-Parts List Important Safety InstructionsTable of Contents Models Spring Operated Fluid RegulatorsAir Operated Fluid Regulators 307212 Pressurized Equipment Hazard Installation Spring Operated InstallationPilot Regulator Air Supply Line Air Operated Installation Before Installing the Fluid Regulator Installing the Fluid RegulatorPressure Relief Procedure Flushing ProcedureOperation Adjust the fluid regulator to the desired setting Regulating Fluid PressurePage Troubleshooting Problem Cause SolutionService Service of the Air Operated RegulatorsModels 214980 shown Air Bleed HoleService of the Spring Operated Regulators Models 217314 Models 214895, 214706, 255374, and 24A082Parts Model 214895, Series HModel 214706, Series H Without gauge. Includes items 1-26Model 255374, Series a Model 24A082, Series a Includes itemsModel 217314, Series F Model 221118, Series EWith gauge. Includes items 1-32 Without gauge. Includes items 1-26 21 *3Model 214980 Series F Includes items 2040Model 244375 Series B Dimensions Gauge PortTechnical Data Category Data30-700 kPa, 0.3-7.0 bar Model 214980 0-30 psi 0-210 kPa, 0-2 barPerformance Chart Graco Standard Warranty Graco Information