WARNING

PRESSURIZED EQUIPMENT HAZARD

Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury.

DDo not stop or deflect fluid leaks with your hand, body, glove, or rag.

DFollow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve the pressure; stop spraying; clean, check, or service the equipment; and install or clean the fluid nozzle.

DTighten all the fluid connections before operating the equipment.

DCheck the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately. Permanently coupled hoses cannot be repaired; replace the entire hose.

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result INSTRUCTIONS in a serious injury.

DThis equipment is for professional use only.

DRead all the instruction manuals, tags, and labels before operating the equipment.

DUse the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor.

DDo not alter or modify this equipment. Use only genuine Graco parts and accessories.

DCheck the equipment daily. Repair or replace worn or damaged parts immediately.

DDo not exceed the maximum working pressure of the lowest rated system component.

DUse fluids that are compatible with the equipment wetted parts. See the Technical Data section of all the equipment manuals. Read the fluid manufacturer’s warnings.

DNever use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents, or fluids containing such solvents in these regulators. In the event that there is a diaphragm failure, a serious chemical reaction could occur, with the possibility of explosion.

DRoute the hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 180_F (82_C) or below –40_F (–40_C).

DNever kink or over bend the hoses or use the hoses to pull equipment.

DComply with all applicable local, state, and national fire, electrical, and other safety regulations.

307212 5

Image 5
Contents Important Safety Instructions Instructions-Parts ListTable of Contents Air Operated Fluid Regulators ModelsSpring Operated Fluid Regulators 307212 Pressurized Equipment Hazard Pilot Regulator Air Supply Line Air Operated Installation InstallationSpring Operated Installation Installing the Fluid Regulator Before Installing the Fluid RegulatorOperation Pressure Relief ProcedureFlushing Procedure Regulating Fluid Pressure Adjust the fluid regulator to the desired settingPage Problem Cause Solution TroubleshootingService of the Air Operated Regulators ServiceAir Bleed Hole Models 214980 shownService of the Spring Operated Regulators Models 214895, 214706, 255374, and 24A082 Models 217314Model 214895, Series H PartsModel 214706, Series H Without gauge. Includes items 1-26Includes items Model 255374, Series a Model 24A082, Series aModel 221118, Series E Model 217314, Series FWith gauge. Includes items 1-32 Without gauge. Includes items 1-26 21 *3Includes items 2040 Model 214980 Series FModel 244375 Series B Gauge Port DimensionsCategory Data Technical Data30-700 kPa, 0.3-7.0 bar Model 214980 0-30 psi 0-210 kPa, 0-2 barPerformance Chart Graco Information Graco Standard Warranty