OPERATION
set by the Ratio parameter. Turn the ATTACK knob
9 – Ratio
This parameter determines how hard the signal is compressed – see the illustration on the previous page. Turn clockwise for more extreme compression. For more information, refer to this manual’s “Suggested Settings” section.
10 – Meter
In Compressor Mode, the meter indicates the current attenuation (compression) of the signal while you are playing. In Noise Gate Mode, the meter indicates the amount of attenuation of the signal when the gate is active.
11 + 14 – Algorithm
Use these switches to select the algorithms for the two channels. The options are:
Studio (Compressor):
This is a subtle compression type. It ensures that your guitar is present with a constant level in the mix.
The “Studio” compressor mode uses
“Stomp” (Compressor):
The “Stomp” compressor mode gives you the kind of hard compression typically associated with stomp box compressors. Use this mode if you aim for an audible compression effect with either a “twang” or a “popping” sound.
Gate:
In Gate Mode, the engine acts as a noise gate. Read more in the manual section: “Noise Gate”.