Gibson Guitars 1550-07 GUS manual Calibrating Powerheads, Manual Calibration of Powerheads

Page 51

49

CALIBRATING POWERHEADS

The Robot Guitar will be pre-calibrated for a standard .010-.046 set of strings. If you change string gauges, restore factory defaults, or are installing the system yourself, you may first want to calibrate the Powerheads individually using the Motor Calibration Mode as described below. Remember though, each Powerhead is self-regulated with a Dynamic Runtime Algorithm that ensures the change of runtimes according to each string. After several tunings the system will perfect itself automatically.

MANUAL CALIBRATION OF POWERHEADS

Enter Setup Mode and turn to LED I, press display. The Peg and I LEDs will shine white. Now you are ready to calibrate any or all of your Powerheads.

First, turn the MCK to the Powerhead you want to calibrate (selected strings are indicated by solid blue) and press the display once. Strum the string and it will begin to alternate between flashing red and green. Pause a few seconds and strum it again. Repeat this simple procedure while the Powerhead adjusts itself. When the LED for that string changes to the next string in order, you know that the Powerhead you selected first is done. It’s that simple.

Image 51
Contents Page 1550-07 GUS Gibson Guitar Corp Then begin enjoying a lifetime of music with your new Gibson Design and Construction Components Components Solidbody Electric Guitar Page Page Brief History of Gibson Electric Guitars Page Page Page Page Design and Construction Page Page Page Page Page Care and Maintenance Page Page Page Page NEW Technology the Gibson Robot Guitar Basic Operations Master Control Knob MCKAll strings in tune = all LEDs flash blue 3 times Precautions Page Page Function MCK Position Display LEDs Action Remarks Dadgad Tuning Double Dropped Function Action Remarks String UP / String Down Modes To Restring Your Robot Guitar As in the case of replacing a string broken while playing To Activate String UP Mode for a Single StringIntonation Mode only Gibson Models Display LEDs Action Calibration Please Note Setup Mode Exit Setup Release Functions Included in Setup ModeGlobal Instantly Speed Control On / Off Manual Calibration of Powerheads Calibrating PowerheadsBattery Level Charging and Battery InformationCharge Mode Automatic Switch OFF Mode Emergency Charge ModeShort Circuit Warning Lifetime of Music Page Page Page Page Page Page Page USA
Related manuals
Manual 63 pages 58.14 Kb