B l e n d i n g H i g h F i d e l i t y A n d A r c h i t e c t u r e ®
N i l e s A u d i o C o r p o r a t i o n
1 2 3 3 1 S . W . 1 3 0 S t r e e t M i a m i , F l o r i d a 3 3 1 8 6
1 - 3 0 5 - 2 3 8 - 4 3 7 3
1 - 8 0 0 - B u y - H i f i – w w w . n i l e s a u d i o . c o m
© 2 0 0 9 N i l e s A u d i o C o r p o r a t i o n . A l l r i g h t s r e s e r v e d . N i l e s , t h e N i l e s
l o g o s , M i c r o F l a s h e r, M i c r o S e n s o r a n d B l e n d i n g H i g h F i d e l i t y a n d A r c h i t e c t u r e a r e r e g i s t e r e d t r a d e m a r k s o f N i l e s A u d i o C o r p o r a t i o n . A l l o t h e r t r a d e m a r k s a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s . D S 0 0 6 7 1 A
Installation
If you are installing the MS120 into an existing wall, take time to consider any possible obstructions which may be hidden inside the wall, such as wood or metal studs; electrical, telephone or other types of wiring; plumbing; AC or heating conduits; old wall safes; etc.
1.Determine a mounting location for the MS120.
Select a location where you will have access to the rear of the MS120 after it is installed. This will allow you to securely tighten the MS120 to the mounting surface using the supplied hardware.
2.Drill a 1/2” hole where the MS120 will be mounted.
3.Run the MS120’s IR cable. Label the cable for future reference. The MS120 is supplied with
10’ of pre-stripped IR cable. The IR cable may be shortened or lengthened as needed. If you want to make the MS120’s cable shorter, use a pair of wire cutters to cut the cable to the desired length. The IR cable may be lengthened by splicing it to a recommended IR cable (See
Installation Considerations—Type of Cable). You may splice the MS120 cable to another cable by soldering or crimping the connections.
4.Connect the MS120 cable to the main system unit. Strip 1/4” of insulation from the end of each wire. Tightly twist the end of each wire until there are no frayed ends. Insert the end of
9
each wire into the appropriate hole on the main system units’ screwless connector (Figure 2), and snap the locking tab down. To help you, the connector plug is keyed. Insert the smooth side of the connector plug into the smooth side of the socket. Don’t force the scalloped side of the connector plug into the smooth side of the socket.
6.Secure the MS120 by tightening the hex nut.
DO NOT OVER-TIGHTEN.
Tools Required
•1/8” Standard Slotted Screwdriver
•Adjustable wrench or pliers
•Wire Stripper
NOTE: Do not install the MS120 next to a light dimmer
OPERATION
Operation of the MS120 is straightforward. Simply aim your hand-held remote at the MS120. Your IR command is instantly repeated to your A/V equipment.
10
TROUBLESHOOTING
This manual contains instructions for the MS120 only. For specific information on the adjustment and operation of your Niles infrared extender system, please refer to the instruction manual included with your Niles IR main system unit (MSU140, MSU250, MSU480 MSU440Z).
1.Test the remote control(s) by operating the
A/V equipment directly. Replace the batteries if needed.
2.Double check the cable connections on the
MS120 and on the main system unit. Look for open, shorted or reversed wires.
3.Test for interference from the following sources:
•Neon, Compact Florescent Lighting (CFL), or halogen lights in the room
•Light dimmers, beginning with those closest to the MS120
Observe the main system unit IR confirmation LED while performing all the tests. It is possible to have interference from more than one source.
Eliminating Optical Feedback
In some installations, two conditions combine to create an optical feedback loop. Symptoms can include: poor range, intermittent operation or no operation.
11
The conditions which sometimes combine to create a feedback loop are:
1.Both a sensor and a flasher are located within the same room.
2.There is some low-level noise or interference on your system.
You can eliminate optical feedback by replacing any IRB1 “flooding flasher” with an MF1 or MF2 MicroFlasher® and covering all flashers with the supplied IR blocking covers.
EMI (Electromagnetic Interference)
Identify the source of the interference. The most common sources of electromagnetic interference are listed in the Installation Considerations section. To eliminate EMI try the following methods:
1.Move the sensor or the sensor cable away from the EMI source or move the source of the EMI away from the sensor or the cable.
2.Connect the Sensor’s GND terminal to true earth ground (if this isn’t feasible use the main system unit’s GND terminal).
There are many methods for reducing interference. Which solution is best for you depends on your situation. If you require further assistance call Niles Technical Support at 305-238-4373 or 1-800-289-4434
(M-F 8:00 AM - 7:00PM ET).
You can also email Niles Technical Support at support@nilesaudio.com.
12
SPECIFICATIONS
IR System
Compatible with virtually all brands of remotes using carrier frequencies between 25kHz and 90kHz
IR Receiving Range
Varies depending on remote strength;
typically 20' to 35' (6.10 meters to 10.68 meters)
IR Receiving Angle
30° off-axis (horizontal and vertical) at 25' (7.62 meters)
Mounting
Thru-hole, fits into a 1/2" (1.27 cm) diameter hole; requires a minimum of 2-7/8" (7.31 cm) mounting depth
Wiring Requirements
Individual home-run of CAT-5 cable
Unit Dimensions
Front Bezel:
3/4" (1.91 cm) diameter x 1/4" (.64 cm) high
Overall Unit:
1/2" (1.27 cm) diameter x 2-7/8" (7.31 cm) long
Contents
MS120 Sensor x 1
Washer x 1
Hex Nut x 1
Black and White Bezel
13
Limited Warranty
Niles Audio Corporation (“NILES”) warrants its Active products (those not requiring AC or battery power) to the original purchaser to be free of manufacturing defects in material and workmanship for a period of tWO years from date of purchase.
This Warranty is subject to the following additional conditions and limitations. The Warranty is void and inapplicable if NILES deems that the product has been used or handled other than in accordance with the instructions provided by the manufacturer, including but not limited to damage caused by accident, mishandling, improper installation, abuse, negligence, or normal wear and tear, or any defect caused by repair to the product by anyone other than NILES or an authorized NILES dealer.
To obtain warranty service, take the unit to the nearest authorized NILES dealer, who will test the product and if necessary, forward it to NILES for service. If there are no authorized NILES dealers in your area, you must write to NILES and include your name, model and serial number of your unit, along with a brief description of the problem. A factory Return Authorization Number will be sent to you. DO NOT RETURN ANY UNIT WITHOUT FIRST RECEIVING WRITTEN AUTHORIZATION AND SHIPPING INSTRUCTIONS FROM NILES.
If the above conditions are met, the purchaser’s sole remedy shall be to return the product to NILES, in which case NILES will repair or replace, at its sole option, the defective product without charge for parts or labor. NILES will return a unit repaired or replaced under warranty by shipping same by its usual shipping method from the factory (only) at its expense within the United States of America. THERE ARE NO OTHER WARRANTIES, INCLUDING
WITHOUT LIMITATION, EITHER EXPRESS OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PRODUCT.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER/PURCHASER. NILES SHALL NOT BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES EXCEPT TO THE EXTENT PROVIDED (OR PROHIBITED) BY APPLICABLE LAW.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For the name of your nearest authorized NILES dealer contact: NILES AUDIO CORPORATION, P.O. BOX 160818, Miami, Florida 33116-0818.
Please fill in your product information and retain for your records.
MS120 Model__________________Purchase Date_ _________________
Serial No.____________________________________________
I N S T A L L A T I O N & O P E R A T I O N G U I D E
Flush-Mount IR microsensor®
MS120