ADDITIONAL INFORMATION
Rear DIP Switch Options
The rear of the
Switch number “1” alters the meter scaling between:
0 dbfs= +18 dBu or 0 dbfs= +24 dbu
Note: that the default factory setting is set to +24 dBu
The Diagnostics 1,2, and 3 switches are for internal SSL factory use only and should not be engaged by the user without dire repercussions on a truly monumental scale. Well perhaps not that bad, but please don’t do it!
Cascading X-Panda and X-Desk
One of the most useful features of the
It is possible to connect an
Currently we recommend that you connect no more than 8
As mentioned, once connected the MIX, CUE, FX 1&2 and AFL solo Busses are combined on the master
So for example:
If you engage SOLO on any channel, all other Channels in your cascaded X- Panda/Desk System will mute.
A single FX processing unit can be connected to the FX 1 or 2 output of the Master Desk yet can be fed audio from sends on any of the cascaded desks.
More advanced users may wish to consider the possibilities of such delights as parallel compression, differing FX destinations, extremely complex Cue sends and a whole host of other creative possibilities
8