Sound Performance Lab 9631 manual Connections, Installing Updates

Page 6

Connections

Rear Panel Spectralizer

Before connecting the SPECTRALIZER switch the power off at all connected units.

The rear panel provides AES/EBU- and S/P-DIF-inputs and outputs. Any additional channel, status and user-bits are passed through unaltered, and the outputs can be used at the same time if required.

The SPECTRALIZER operates with 24 bit word width. It accepts 16 bit and 20 bit inputs and will create output signals accor- ding to the input resolution.

For synchronisation purposes WORDCLOCK IN and WORDCLOCK THROUGH BNC connectors are fitted with a switchable 75 Ohm termination.

MIDI IN and MIDI THROUGH connectors allow presets to be selected via MIDI program change commands.

For easy upgrade of future software releases, the rear panel offers RS-232 interface for PC and RS-422 interface for MAC.

Installing Updates:

Note: All presets will be lost after installing a new software version!

1.Connect your computer with the SPECTRALIZER via a serial port with a standard Z-modem cable.

RS-232 for PC and RS-422 for MAC.

2.Open a terminal program like “Hyperterminal” on PC and make the following adjustments:

Baud rate: 9600; Stop bit: 1; Parity: none; Data bit: 8;

Handshake: no; Transfer mode: ZMODEM

3.Switch on the SPECTRALIZER and depress both

PRESET UP and PRESET DOWN until the LC-display says “wait for Zmodem download“.

4.Load the update file into your terminal program and send it to the SPECTRALIZER. The LC-display shows the progress of the download in kB.

5.After successfully installing the new software version the LC-display says “download valid”.

6.Switch the SPECTRALIZER off and on. The new software version number is displayed in the first INFO page (simultaneously depress STORE and APPLY; also refer to CONTROL ELEMENTS No. 9, INFO).

7.If an error occurred during download the LC-display says “download failed”. The SPECTRALIZER now waits

for a new download. Please check all adjustments on your terminal program and try again. If you are still unsuccessful contact your local dealer.

6

Spectralizer

Image 6
Contents Spectralizer Model By Hermann Gier and Paul White Version 2.2 1/1999 NFO Hardware dialogue Contents Foreword Thanks Specifications Warranty Dear customer We wish you every success with the SpectralizerIntroduction Operation Safety SpectralizerInstalling Updates ConnectionsSet all controls to the starting positions Flow ChartQuick-Start Depress ACTIVE. The status-LED illuminatesInput Gain Control ElementsActive Illuminated LED indicates that the processing is activatedDiagram Frequency Mix 2nd Harmonic3rd Harmonic Density LC-display Solo Kick Preset Info Software version and date Selecting inputsDisplaying the CRC-Error flag Displaying the Audio-Error flagNo = no error detected YES = error detected Displaying the detected sample frequencyDisplaying the Original flag Displaying the Channel Difference Error flagSetting or erasing the Copy-Prohibit flag Displaying the Emphasis flagMidi Implementations Last 3dB before 0dBSpecifications Input/OutputWarranty