Ingersoll-Rand 651747-2-M manual Trouble Shooting, Accessories

Page 4

TROUBLE SHOOTING

Fluid heater will not produce heat.

No current to the heater unit. Check the main power switch. Check the power supply fuse, etc.

Damaged thermostat.

Replace the thermostat.

The heat limiter is burned out. Replace the heat limiter.

The heat element is burned out. Replace the heater cartridge element.

The temperature of the material is too low.

The voltage to the heater is too low. Correct the wiring.

The thermostat is damaged. Replace the thermostat.

The thermostat setting is wrong. Adjust the thermostat.

Material build-up inside the heater.

Clean the fluid heater and material lines.

The material flow is too fast. Reduce the material flow.

The temperature of the material is too high.

The thermostat is damaged. Replace the thermostat.

Wrong setting on the thermostat. Reset the thermostat.

The heater takes too long to heat the material.

The voltage is too low.

Correct the wiring.

Material build-up inside the heater.

Clean the fluid heater and material lines.

Inadequate material flow.

Material build-up inside the heater.

Clean the fluid heater and material lines.

TYPICAL INSTALLATION

TYPICAL SINGLE HEATER

TYPICAL DUAL HEATER

“C”“C”

“A”“A”

“B”“B”

“A” = Material Outlet

“B” = Material Inlet

“C” = Power In

Figure 4

ACCESSORIES

66258 Mounting Bracket Assembly

6” (152.4 mm)

11/16” (17.5 mm)

2-1/4”

(57.2 mm)

1-11/16”

(42.9 mm)

3/8” dia. (9.5 mm) 6x

Figure 5

 

PN 97999-1052

 

 

Page 4 of 4

651747-2-M

Image 4
Contents Typical Installation Dimensional DataOperating Precautions Fluid Heater DataPower Supply and Installation MaintenanceDisassembly ReassemblyParts List / 651747-2-M Trouble Shooting Accessories